肝脏射频消融:SPION增强巨噬细胞特异性MRI监测消融诱导的消融周边巨噬细胞募集
结果显示消融周边信号强度丢失面积进行性增加并于3周达峰,相对信号强度比显著下降,反映铁负载巨噬细胞累积。结论为SPION增强MRI可无创监测和量化消融诱导的巨噬细胞募集。
要点
- SPION增强T2*加权MRI可在活体显示消融周边铁负载巨噬细胞的进行性累积。
- 消融周边信号强度丢失面积于RFA后3周达峰,相对信号强度比显著下降。
- 该技术有望用于指导肝脏RFA后辅助治疗以调节消融周边炎症。
核心结论
- SPION增强MRI能够无创监测和量化肝脏射频消融后消融周边巨噬细胞募集。
- 消融诱导的消融周边炎症与RFA潜在致瘤效应密切相关,SPION增强MRI可能有助于指导和调节RFA后辅助治疗。
研究设计与样本
- RFA后立即至3周行MRI,并在SPION注射前和注射后24小时扫描,分析T2*加权图像。
- 以组织病理学和免疫组化作为参考标准,并与ICP-MS及LA-ICP-MS铁定量进行相关性分析。
关键影像表现/征象
- SPION增强T2*加权MRI显示消融周边信号强度丢失区域进行性增加,于RFA后3周达峰。
- 信号强度定量分析显示相对信号强度比显著下降,反映消融周边铁负载巨噬细胞累积增多。
- 组织学分析证实消融周边铁负载巨噬细胞进行性累积。
- ICP-MS和LA-ICP-MS证实消融周边铁浓度进行性增加。
临床应用与阅片要点
- 阅片时关注SPION注射前后T2*加权图像上消融周边信号强度丢失区域的范围及其随时间的变化。
- 可计算相对信号强度比以量化消融周边铁负载巨噬细胞累积程度。
- 需在SPION注射前和注射后24小时分别扫描,以区分基线信号与巨噬细胞摄取所致信号改变。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: Macrophages accumulating in the periablational rim play a pivotal role in initiating and sustaining the perifocal inflammatory reaction, which has been shown to be at least 1 of the mechanisms responsible for the systemic pro-oncogenic effects of focal hepatic radiofrequency ablation (RFA). Herein, we tested the hypothesis to use superparamagnetic iron oxide nanoparticle (SPION)-enhanced magnetic resonance imaging (MRI) for noninvasive quantification of iron-loaded macrophages in the periablational rim of VX2 tumor-bearing rabbits.
MATERIALS AND METHODS: Twelve VX2 tumor-bearing rabbits underwent MRI immediately after and up to 3 weeks after focal hepatic RFA. For noninvasive quantification of macrophage accumulation in the periablational rim, animals were scanned before and 24 hours after SPION injection. T2*-weighted images were analyzed and correlated with histopathological and immunohistochemical findings. Furthermore, correlations with quantitative measurements (ICP-MS [inductively coupled plasma-mass spectrometry] and LA-ICP-MS [laser ablation-ICP-MS]) were performed.
RESULTS: SPION-enhanced T2*-weighted MRI scans displayed a progressive increase in the areas of signal intensity (SI) loss within the periablational rim peaking 3 weeks after RFA. Accordingly, quantitative analysis of SI changes demonstrated a significant decline in the relative SI ratio reflecting a growing accumulation of iron-loaded macrophages in the rim. Histological analyses confirmed a progressive accumulation of iron-loaded macrophages in the periablational rim. The ICP-MS and LA-ICP-MS confirmed a progressive increase of iron concentration in the periablational rim.
CONCLUSIONS: SPION-enhanced MRI enables noninvasive monitoring and quantification of ablation-induced macrophage recruitment in the periablational rim. Given the close interplay between ablation-induced perifocal inflammation and potential unwanted tumorigenic effects of RFA, SPION-enhanced MRI may serve as a valuable tool to guide and modulate adjuvant therapies after hepatic RFA.
引用
- Collettini F, Brangsch J, Reimann C, et al. Hepatic Radiofrequency Ablation: Monitoring of Ablation-Induced Macrophage Recruitment in the Periablational Rim Using SPION-Enhanced Macrophage-Specific Magnetic Resonance Imaging. Invest Radiol. 2021. PMID: 33787536. doi:10.1097/RLI.0000000000000777
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。