文献速递腹部骨肌技术与安全CT

CT影像组学模型鉴别骨岛与成骨性骨转移的开发与验证

Development and Validation of a Radiomics Model for Differentiating Bone Islands and Osteoblastic Bone Metastases at Abdominal CT.
PubMed 文献 · Radiology · 2021-03-30

基于CT影像组学的随机森林模型能有效鉴别骨岛与成骨性骨转移,外部测试AUC为0.96。

要点

  • 腹部增强CT影像组学随机森林模型可鉴别骨岛与成骨性骨转移,外部测试AUC 0.96。
  • 模型敏感度80%、特异度96%,特异度高于敏感度,有助于减少误判转移。

核心结论

  • 基于CT影像组学的随机森林模型能有效鉴别骨岛与成骨性骨转移,外部测试AUC为0.96。

研究设计与样本

  • 回顾性研究,纳入2015至2019年两家机构接受腹部增强CT且诊断为骨岛或成骨性骨转移的患者。
  • 机构1患者为训练集(177例:骨岛89例,转移88例;平均年龄66岁±12;男111例)。
  • 机构2患者为外部测试集(64例:骨岛23例,转移41例;平均年龄69岁±14;男59例)。
  • 提取1218个影像组学特征,选取10个特征构建随机森林模型,并进行10折交叉验证。
  • 测试阶段由3名放射科医生独立阅片,计算并比较模型与医生的敏感度、特异度、准确率及AUC。

诊断标准与关键数值

  • 训练集10折交叉验证平均AUC 0.89,敏感度85%(75/88),特异度82%(73/89),准确率84%(148/177)。
  • 外部测试集模型AUC 0.96,敏感度80%(33/41),特异度96%(22/23),准确率86%(55/64)。
  • 3名放射科医生AUC分别为0.95(95%CI:0.90,1.00)、0.96(95%CI:0.90,1.00)、0.88(95%CI:0.80,0.96)。

临床应用与阅片要点

  • 对于腹部CT上发现的硬化性骨病灶,可借助影像组学模型辅助鉴别骨岛与成骨性骨转移。
  • 模型特异度高达96%,有助于减少将骨岛误判为转移,但敏感度80%提示阴性结果仍需结合临床。
  • 经验不足的放射科医生可参考模型输出,但模型不能替代医生综合判断。
  • 需注意模型基于增强腹部CT和特定机构数据构建,外推至其他扫描参数或人群时需谨慎验证。

局限性

  • 回顾性研究设计,可能存在选择偏倚。
  • 外部测试集样本量较小(64例),结论需更大样本验证。
  • 模型仅与3名放射科医生比较,且仅对第3名医生有显著优势。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Background It is important to diagnose sclerotic bone lesions in order to determine treatment strategy. Purpose To evaluate the diagnostic performance of a CT radiomics-based machine learning model for differentiating bone islands and osteoblastic bone metastases. Materials and Methods In this retrospective study, patients who underwent contrast-enhanced abdominal CT and were diagnosed with a bone island or osteoblastic metastasis between 2015 to 2019 at either of two different institutions were included: institution 1 for the training set and institution 2 for the external test set. Radiomics features were extracted. The random forest (RF) model was built using 10 selected features, and subsequent 10-fold cross-validation was performed. In the test phase, the RF model was tested with an external test set. Three radiologists reviewed the CT images for the test set. The sensitivity, specificity, accuracy, and area under the receiver operating characteristic curve (AUC) were calculated for the models and each of the three radiologists. The AUCs of the radiomics model and radiologists were compared. Results A total of 177 patients (89 with a bone island and 88 with metastasis; mean age, 66 years ± 12 [standard deviation]; 111 men) were in the training set, and 64 (23 with a bone island and 41 with metastasis; mean age, 69 years ± 14; 59 men) were in the test set. Radiomics features (n = 1218) were extracted. The average AUC of the RF model from 10-fold cross-validation was 0.89 (sensitivity, 85% [75 of 88 patients]; specificity, 82% [73 of 89 patients]; and accuracy, 84% [148 of 177 patients]). In the test set, the AUC of the trained RF model was 0.96 (sensitivity, 80% [33 of 41 patients]; specificity, 96% [22 of 23 patients]; and accuracy, 86% [55 of 64 patients]). The AUCs for the three readers were 0.95 (95% CI: 0.90, 1.00), 0.96 (95% CI: 0.90, 1.00), and 0.88 (95% CI: 0.80, 0.96). The AUC of radiomics model was higher than that of only reader 3 (0.96 vs 0.88, respectively; P = .03). Conclusion A CT radiomics-based random forest model was proven useful for differentiating bone islands from osteoblastic metastases and showed better diagnostic performance compared with an inexperienced radiologist. © RSNA, 2021 Online supplemental material is available for this article. See also the editorial by Vannier in this issue.

来源:Radiology,查看原文。版权归原作者所有。

引用

  1. Hong JH, Jung JY, Jo A, et al. Development and Validation of a Radiomics Model for Differentiating Bone Islands and Osteoblastic Bone Metastases at Abdominal CT. Radiology. 2021. PMID: 33787335. doi:10.1148/radiol.2021203783

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。