文献速递腹部技术与安全CT

基于正弦图的深度学习图像重建在腹部CT中的图像质量评估

Sinogram-based deep learning image reconstruction technique in abdominal CT: image quality considerations.
PubMed 文献 · Eur Radiol · 2021-04-23

该回顾性研究纳入50例患者,比较腹部CT门静脉期基于正弦图的深度学习重建(DLIR)三种强度与ASIR-V 40%的图像质量。三种DLIR在噪声、对比度、小结构可见性和锐利度主观评分及客观噪声、CNR上均优于ASIR-V,DLIR-H最佳,伪影评分无差异。

要点

  • DLIR各强度主观图像质量评分均优于ASIR-V,DLIR-H最佳
  • DLIR较ASIR-V提高CNR 26.38%–102.30%、降低噪声20.64%–48.77%
  • 各重建伪影评分无显著差异,DLIR不改变主观纹理感知

关键影像表现/征象

  • DLIR-H在噪声、对比度、小结构可见性和锐利度的主观评分分别为1.40±0.53、1.41±0.55、1.51±0.61、1.60±0.54,为最佳(p<0.05)。
  • DLIR-M各主观评分依次为1.85±0.52、1.66±0.57、1.69±0.59、1.68±0.46,DLIR-L为2.29±0.58、1.96±0.61、1.90±0.65、1.86±0.46,ASIR-V为2.86±0.67、2.55±0.58、2.34±0.66、2.01±0.36。
  • 各重建伪影评分相似(p>0.05),DLIR不改变主观纹理感知,且从一开始即被优先选择。

诊断标准与关键数值

  • 主观图像质量采用5分制评分(1分=极好,5分=极差),由三名盲法放射科医师评定噪声、对比度、小结构可见性、锐利度和伪影。
  • 图像偏好采用3分制(1分=最偏好,3分=最不偏好)。
  • 客观评估测量图像噪声和对比噪声比(CNR);所有DLIR较ASIR-V的CNR提高26.38%–102.30%,噪声降低20.64%–48.77%,DLIR-H客观评分最佳。

临床应用与阅片要点

  • DLIR-H在噪声、对比度、小结构可见性和锐利度上主观评分最佳,日常阅片可优先选用高强度的DLIR以获得更优图像质量。
  • DLIR较ASIR-V显著降低图像噪声并提高CNR,有利于体型较大患者的腹部CT图像判读,可能允许进一步优化辐射剂量。
  • 各重建伪影评分无显著差异且DLIR不改变主观纹理感知,报告时可关注其噪声降低优势而无需担忧新增伪影干扰。

局限性

  • 回顾性单中心研究,样本量50例,参考标准未报告,结果外推需谨慎。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To investigate the image quality and perception of a sinogram-based deep learning image reconstruction (DLIR) algorithm for single-energy abdominal CT compared to standard-of-care strength of ASIR-V.

METHODS: In this retrospective study, 50 patients (62% F; 56.74 ± 17.05 years) underwent portal venous phase. Four reconstructions (ASIR-V at 40%, and DLIR at three strengths: low (DLIR-L), medium (DLIR-M), and high (DLIR-H)) were generated. Qualitative and quantitative image quality analysis was performed on the 200 image datasets. Qualitative scores were obtained for image noise, contrast, small structure visibility, sharpness, and artifact by three blinded radiologists on a 5-point scale (1, excellent; 5, very poor). Radiologists also indicated image preference on a 3-point scale (1, most preferred; 3, least preferred). Quantitative assessment was performed by measuring image noise and contrast-to-noise ratio (CNR).

RESULTS: DLIR had better image quality scores compared to ASIR-V. Scores on DLIR-H for noise (1.40 ± 0.53), contrast (1.41 ± 0.55), small structure visibility (1.51 ± 0.61), and sharpness (1.60 ± 0.54) were the best (p < 0.05) followed by DLIR-M (1.85 ± 0.52, 1.66 ± 0.57, 1.69 ± 0.59, 1.68 ± 0.46), DLIR-L (2.29 ± 0.58, 1.96 ± 0.61, 1.90 ± 0.65, 1.86 ± 0.46), and ASIR-V (2.86 ± 0.67, 2.55 ± 0.58, 2.34 ± 0.66, 2.01 ± 0.36). Ratings for artifacts were similar for all reconstructions (p > 0.05). DLIRs did not influence subjective textural perceptions and were preferred over ASIR-V from the beginning. All DLIRs had a higher CNR (26.38-102.30%) and lower noise (20.64-48.77%) than ASIR-V. DLIR-H had the best objective scores.

CONCLUSION: Sinogram-based deep learning image reconstructions were preferred over iterative reconstruction subjectively and objectively due to improved image quality and lower noise, even in large patients. Use in clinical routine may allow for radiation dose reduction.

KEY POINTS: • Deep learning image reconstructions (DLIRs) have a higher contrast-to-noise ratio compared to medium-strength hybrid iterative reconstruction techniques. • DLIR may be advantageous in patients with large body habitus due to a lower image noise. • DLIR can enable further optimization of radiation doses used in abdominal CT.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Parakh A, Cao J, Pierce TT, et al. Sinogram-based deep learning image reconstruction technique in abdominal CT: image quality considerations. Eur Radiol. 2021. PMID: 33893535. doi:10.1007/s00330-021-07952-4

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。