动态增强光声成像定量评估小鼠肝纤维化
本研究用动态增强光声成像监测四氯化碳诱导的小鼠肝纤维化模型,计算吲哚菁绿肝功能曲线的Tmax和T1/2。结果显示这两个参数随纤维化分期升高,且与病理评分正相关,提示可用于无创定量评估肝纤维化。
要点
- 光声成像可无创动态监测ICG在肝脏的药代动力学。
- Tmax和T1/2随纤维化进展而延长,与病理评分正相关。
- 该技术有望用于肝纤维化的定量功能评估。
核心结论
- 动态增强光声成像显示诱导纤维化小鼠的Tmax和T1/2高于无纤维化对照,且与组织学纤维化指标相关。
研究设计与样本
- 研究纳入28只8周龄雄性小鼠,每2天腹腔注射四氯化碳建立肝纤维化模型。
- 在建模第1、4、8周动态监测肝脏结构变化,计算不同病理阶段及对照组的ICG Tmax和T1/2。
- 获取相应肝脏组织病理结果和血液生化数据,采用Spearman秩相关评估DCE PAI结果与组织学评分的关系。
关键影像表现/征象
- 光声肝功能曲线显示各组Tmax和T1/2存在差异:对照组Tmax为9秒±1.8,1周为51秒±4.4,4周为73秒±5.3,8周为104秒±6.6(P < .001)。
- 对照组T1/2为28秒±6.5,1周为201秒±12.4,4周为285秒±11,8周为318秒±30.5(P < .001)。
诊断标准与关键数值
- Tmax与Sirius红染色面积和αSMA阳性面积的Spearman ρ分别为0.93和0.94(P均< .001)。
- T1/2与Sirius红染色面积和αSMA阳性面积的Spearman ρ分别为0.87和0.89(P均< .001)。
临床应用与阅片要点
- 阅片时可关注ICG肝功能曲线的Tmax和T1/2,其延长提示纤维化可能。
- 报告时可结合Tmax和T1/2与病理评分的正相关性,提示纤维化程度。
局限性
- 研究为动物实验,样本量28只,结论外推至人类需谨慎。
- 仅监测至建模第8周,未涵盖更长期纤维化进展。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Background Dynamic contrast-enhanced (DCE) photoacoustic (PA) imaging (PAI) is a novel noninvasive imaging modality that uses the differences in optical absorption of oxyhemoglobin and deoxyhemoglobin and may be performed in a dynamic fashion to image the indocyanine green (ICG) pharmacokinetics in the liver. Purpose To determine whether DCE PAI parameters (maximum peak time [Tmax] and half-life [T1/2]) derived from the PA liver function curve correlate with fibrosis determined using histopathologic analysis. Materials and Methods Between June 2020 and October 2020, 28 male mice aged 8 weeks were intraperitoneally injected with carbon tetrachloride solution every 2 days to establish a liver fibrosis model. At the 1st, 4th, and 8th week of modeling, the changes in liver structure were monitored dynamically by using a PA technique. The Tmax and T1/2 of ICG were calculated at different pathologic stages and within a control group. Corresponding liver histopathologic results and blood biochemical data were obtained. Spearman rank correlation was used to evaluate the relationship between the DCE PAI results and histologic scores. Results The PA liver function curve showed that the Tmax and T1/2 varied among groups (mean Tmax: control group, 9 seconds ± 1.8 [standard deviation]; 1 week, 51 seconds ± 4.4; 4 weeks, 73 seconds ± 5.3; 8 weeks, 104 seconds ± 6.6; P < .001) (mean T1/2: control group, 28 seconds ± 6.5; 1 week, 201 seconds ± 12.4; 4 weeks, 285 seconds ± 11; 8 weeks, 318 seconds ± 30.5; P < .001). There was a positive correlation between the dynamic parameters (Tmax and T1/2) and the histopathologic scores; the Spearman ρ ratios for the Sirius red and α-smooth muscle actin (αSMA)-positive areas versus the Tmax were 0.93 and 0.94 (P < .001 for both), and the Spearman ρ ratios for the Sirius red and αSMA-positive areas versus T1/2 were 0.87 and 0.89 (P < .001 for both). Conclusion Dynamic contrast-enhanced photoacoustic imaging demonstrated a higher maximum peak time and half-life in mice with induced fibrosis compared with control mice without fibrosis, and these values correlated with histologic measures of fibrosis. © RSNA, 2021 Online supplemental material is available for this article.
引用
- Lv J, Xu Y, Xu L, et al. Quantitative Functional Evaluation of Liver Fibrosis in Mice with Dynamic Contrast-enhanced Photoacoustic Imaging. Radiology. 2021. PMID: 33904773. doi:10.1148/radiol.2021204134
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。