文献速递腹部MR

扩散MRI用于胰腺导管腺癌特征分析的诊断效能:一项Meta分析

Diagnostic performance of diffusion MRI for pancreatic ductal adenocarcinoma characterisation: A meta-analysis.
PubMed 文献 · Eur J Radiol · 2021-03-20

ADC的汇总敏感度83%、特异度85%、AUC 0.91;IVIM中灌注分数诊断准确性最高,AUC 0.93。DWI与IVIM诊断效能相当且均良好。

要点

  • ADC诊断PDAC的汇总敏感度83%、特异度85%、AUC 0.91。
  • IVIM灌注分数诊断准确性最高,AUC 0.93。
  • 研究设计、ROI勾画、场强和层厚是ADC异质性来源。

核心结论

  • DWI和IVIM对PDAC特征分析具有相当且良好的诊断效能。

研究设计与样本

  • 26项研究评估ADC,8项评估IVIM,其中5项同时评估ADC和IVIM;采用双变量随机效应模型计算汇总敏感度和特异度,并构建SROC曲线计算AUC。
  • 进行亚组和Meta回归分析评估异质性,并评估研究质量。

诊断标准与关键数值

  • ADC汇总敏感度83%(95%CI 76%-88%,I2=86%)、特异度85%(95%CI 79%-90%,I2=77%)、AUC 0.91(95%CI 0.88-0.93)。
  • IVIM灌注分数汇总敏感度87%(95%CI 81%-92%,I2=45%)、特异度88%(95%CI 77%-94%,I2=57%)、AUC 0.93(95%CI 0.91-0.95),为IVIM模型中诊断准确性最高。
  • 组织扩散系数汇总敏感度74%(95%CI 55%-87%,I2=87%)、特异度69%(95%CI 52%-82%,I2=73%)、AUC 0.77(95%CI 0.73-0.81)。
  • 假扩散系数汇总敏感度89%(95%CI 77%-96%,I2=79%)、特异度74%(95%CI 60%-84%,I2=78%)、AUC 0.88(95%CI 0.85-0.91)。

临床应用与阅片要点

  • DWI和IVIM均可用于PDAC的无创特征分析,IVIM灌注分数诊断准确性略高,但ADC应用更广泛。
  • 阅片时需注意研究设计、ROI勾画方式、场强和层厚对ADC诊断异质性的影响。

局限性

  • 纳入研究间存在显著异质性(ADC敏感度I2=86%,特异度I2=77%)。
  • 研究设计、ROI勾画、场强和层厚是ADC异质性的来源,可能影响结果的外推。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To assess the diagnostic performance of intravoxel incoherent motion (IVIM) and diffusion-weighted imaging (DWI) for characterising pancreatic ductal adenocarcinoma (PDAC).

METHOD: A literature search was performed through PubMed, Web of Science, the Cochrane Library, and Embase databases. The search date was updated to extend until 28 October 2020, with no starting time limitation. The pooled sensitivity and specificity were calculated using a bivariate random effects model. Summary receiver operating characteristic curves were constructed, and area under the curve (AUC) of each diffusion parameter was calculated. Subgroup and meta-regression analyses were performed to assess for heterogeneity. Study quality was assessed.

RESULTS: Twenty-nine studies involving 1579 participants were included, of which 26 evaluated the apparent diffusion coefficient (ADC) and eight evaluated IVIM, with five evaluating both ADC and IVIM. Pooled sensitivity and specificity of ADC were 83 % (95 % CI, 76 %-88 %, I2 = 86 %) and 85 % (95 % CI, 79 %-90 %, I2 = 77 %), respectively, and AUC was 0.91 (95 % CI, 0.88-0.93). The perfusion fraction had the highest diagnostic accuracy in the IVIM model; the pooled sensitivity, specificity, and AUC were 87 % (95 % CI, 81 %-92 %, I2 = 45 %), 88 % (95 % CI, 77 %-94 %, I2 = 57 %), and 0.93 (95 % CI, 0.91-0.95), respectively. The pooled sensitivity, specificity and AUC for the tissue diffusion coefficient were 74 % (95 % CI, 55 %-87 %, I2 = 87 %), 69 % (95 % CI, 52 %-82 %, I2 = 73 %), and 0.77 (95 % CI, 0.73-0.81), respectively. And the pooled sensitivity, specificity, and AUC for the pseudodiffusion coefficient were 89 % (95 % CI, 77 %-96 %, I2 = 79 %), 74 % (95 % CI, 60 %-84 %, I2 = 78 %), and 0.88(95 %CI,0.85-0.91), respectively. Meta-regression analyses revealed that study design (specificity, P<0.01), region-of-interest delineation (sensitivity, P = 0.02;specificity, P = 0.03), field strength (sensitivity, P<0.01), and thickness (sensitivity, P<0.01; specificity, P = 0.01) were sources of ADC heterogeneity.

CONCLUSIONS: DWI and IVIM have comparable diagnostic power and good diagnostic performance for characterising PDAC.