儿童及青年肝脏定量MRI中压缩SENSE与SENSE序列的比较
结果显示PDFF和硬度呈极强正相关且偏差极小,而T2*仅呈中度相关且偏差较大。提示C-SENSE可可靠测量PDFF和硬度。
要点
- C-SENSE与SENSE测肝脏PDFF和硬度高度一致,可用于临床定量。
- T2*测量两种序列一致性中等,偏差较大,需谨慎解读。
- 硬度偏差随肝脏硬度增加而增大,高硬度时更需注意。
关键影像表现/征象
- 肝脏PDFF在两种序列间呈极强正相关(r=0.98)。
- 肝脏T2*在两种序列间呈中度正相关(r=0.53)。
- 肝脏硬度在两种序列间呈极强正相关(r=0.97)。
诊断标准与关键数值
- PDFF平均偏差0.28%(95% LOA:-0.85,1.41%)。
- T2*平均偏差-3.0 ms(95% LOA:-12.0,6.0 ms)。
- 硬度平均偏差0.13 kPa(95% LOA:-0.37,0.63 kPa),且偏差随肝脏硬度增加而增大。
临床应用与阅片要点
- C-SENSE可用于临床快速定量肝脏PDFF和硬度,结果与SENSE一致。
- T2*测量在两种序列间存在较大偏差,阅片时需注意序列选择。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: Compressed SENSE (C-SENSE) allows more rapid MRI acquisition through incoherent, pseudorandom k-space undersampling. The purpose of our study was to compare conventional sensitivity encoded imaging (SENSE) quantitative MR images to those obtained using C-SENSE for measurement of liver proton density fat fraction (PDFF), T2*, and stiffness.
METHODS AND MATERIALS: Clinical liver MRI examinations that included SENSE and C-SENSE quantitative MRI sequences were retrospectively identified. Patient age, gender, liver PDFF (%), T2* (ms), and stiffness (kPa) were recorded. Spearman's rank-order correlation (r) was used to evaluate association between methods, and Bland-Altman analysis was used to determine the mean bias and 95% limits of agreement.
RESULTS: Clinical liver MRI examinations that included SENSE and C-SENSE quantitative MRI sequences were retrospectively identified. Patient age, gender, liver PDFF (%), T2* (ms), and stiffness (kPa) were recorded. Spearman's rank-order correlation (r) was used to evaluate association between methods, and Bland-Altman analysis was used to determine the mean bias and 95% limits of agreement. Thirty-six examinations met the inclusion criteria. Mean patient age was 15.7 ± 7.7 years; twelve exams (33%) were in female patients. Liver PDFF showed very strong positive correlation (r = 0.98) between sequences, with a mean bias of 0.28% (95% LOA: -0.85, 1.41%). T2* showed moderate positive correlation (r = 0.53), with a mean bias of - 3.0 ms (95% LOA: - 12.0, 6.0 ms). Stiffness showed very strong positive correlation (r = 0.97), with a mean bias of 0.13 kPa (95% LOA: - 0.37, 0.63 kPa) that increased with increasing liver stiffness.
CONCLUSION: There were strong positive correlations between SENSE and C-SENSE MRI measurements of liver PDFF and stiffness, with no to minimal bias. However, there was moderate correlation and greater negative mean bias between T2* measurements. Our results demonstrate the potential of compressed sensing to reliably measure PDFF and stiffness in the clinic.