基于结局比较SMFM与ISUOG胎儿生长受限定义
本研究为前瞻性队列的二次分析,纳入1054例孕26+0至36+6周因胎儿生长超声转诊的孕妇,比较SMFM与ISUOG两种胎儿生长受限(FGR)定义对新生儿小于胎龄儿(SGA)和复合不良新生儿结局(ANO)的预测效能。SMFM定义检出FGR 137例(13.0%),ISUOG定义检出55例(5.2%);SMFM预测SGA敏感度更高(54.7% vs 28.8%),ISUOG特异度(98.4% vs 93.3%)、阳性似然比(18.0 vs 8.2)和阳性预测值(72.7% vs 55.5%)更高;两种定义预测复合ANO的敏感度均低(15.1%和10.1%)。
要点
- SMFM定义(EFW或AC<第10百分位)对SGA检出敏感度更高,但特异度略低。
- ISUOG定义(Delphi标准)对SGA的阳性预测值和阳性似然比更高。
- 两种定义对复合不良新生儿结局的预测效能均差。
英文原文(摘要)· 点击展开
OBJECTIVE: The recent international guidelines by the Society for Maternal-Fetal Medicine (SMFM) and the International Society of Ultrasound in Obstetrics and Gynecology (ISUOG) differ in their definitions of fetal growth restriction (FGR). Our aim was to compare the performance of the two definitions in predicting neonatal small-for-gestational age (SGA) and composite adverse neonatal outcome (ANO).
METHODS: This was a secondary analysis of data from a prospective study of women referred for fetal growth ultrasound examination between 26 + 0 and 36 + 6 weeks' gestation. The SMFM and ISUOG guidelines were used to define pregnancies with FGR. The SMFM definition of FGR is estimated fetal weight (EFW) or abdominal circumference (AC) < 10th percentile. The ISUOG-FGR definition follows the Delphi consensus criteria and includes either EFW or AC < 3rd percentile or EFW or AC < 10th percentile combined with abnormal Doppler findings or a decrease in growth centiles. The primary outcome was the prediction of neonatal SGA, defined as birth weight < 10th percentile, and a composite of ANO, which was defined as one or more of: Grade-III or -IV intraventricular hemorrhage, respiratory distress syndrome, neonatal death, cord blood pH < 7.1, seizures and admission to the neonatal intensive care unit. Test characteristics (sensitivity, specificity, positive predictive value (PPV), negative predictive value and positive (LR+) and negative likelihood ratios) and area under the receiver-operating-characteristics curve were determined. The association between FGR detected by each definition and selected adverse outcomes was assessed using logistic regression analysis.
RESULTS: Of the 1054 pregnancies that met the inclusion criteria, 137 (13.0%) and 55 (5.2%) were defined as having FGR by the SMFM and ISUOG definitions, respectively. Composite ANO and SGA neonate each occurred in 139 (13.2%) pregnancies. For the prediction of neonatal SGA, the SMFM-FGR definition had a higher sensitivity (54.7%) than did the ISUOG definition (28.8%). The ISUOG-FGR definition had higher specificity (98.4% vs 93.3%), LR+ (18.0 vs 8.2) and PPV (72.7% vs 55.5%) than did the SMFM definition for the prediction of a SGA neonate. The SMFM- and ISUOG-FGR definitions had similarly poor performance in predicting composite ANO, with sensitivities of 15.1% and 10.1%, respectively.
CONCLUSIONS: The SMFM definition of FGR is associated with a higher detection rate for SGA neonates but at the cost of some reduction in specificity. The ISUOG-FGR definition has a higher specificity, LR+ and PPV for the prediction of neonatal SGA. Both definitions of FGR performed poorly in predicting a composite ANO. © 2021 International Society of Ultrasound in Obstetrics and Gynecology.
引用
- Roeckner JT, Pressman K, Odibo L, et al. Outcome-based comparison of SMFM and ISUOG definitions of fetal growth restriction. Ultrasound Obstet Gynecol. 2021. PMID: 33798274. doi:10.1002/uog.23638
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。