文献速递腹部CT

三时相腹部CT诊断和分级食管静脉曲张的准确性研究

Optimal diagnostic tool for surveillance of oesophageal varices during COVID-19 pandemic.
PubMed 文献 · Clin Radiol · 2021-03-18

本研究对104例肝硬化患者回顾性分析三时相腹部CT与内镜在食管静脉曲张诊断和分级中的一致性,结果显示两者分级一致率为81.73%,加权kappa为0.88,CT诊断无、小、中、大静脉曲张的敏感度分别为66.6%、79.3%、89.6%、94.1%,AUROC分别为0.775、0.887、0.839、0.914。结论认为三时相腹部CT可作为COVID-19疫情期间食管静脉曲张诊断和分级的替代工具。

要点

  • 三时相腹部CT与内镜对食管静脉曲张分级一致性高(加权kappa 0.88)。
  • CT诊断大静脉曲张敏感度最高(94.1%),无静脉曲张敏感度较低(66.6%)。
  • APRI、FIB-4、PS评分与静脉曲张严重程度相关,CT与内镜间无差异。

核心结论

  • 三时相腹部CT在COVID-19疫情期间可作为食管静脉曲张诊断和分级的 invaluable 工具。

诊断标准与关键数值

  • CT与内镜分级总体一致率为81.73%(85/104),加权kappa为0.88(95%CI 0.82-0.94)。
  • CT诊断无、小、中、大静脉曲张的敏感度分别为66.6%、79.3%、89.6%、94.1%,AUROC分别为0.775、0.887、0.839、0.914。
  • APRI、FIB-4、PS评分与静脉曲张严重程度相关,内镜与CT分级间无差异。

临床应用与阅片要点

  • 在疫情期间或内镜受限时,可考虑使用三时相腹部CT评估食管静脉曲张并分级。
  • CT对中大静脉曲张诊断敏感度高,但对无静脉曲张的排除敏感度较低,需结合临床和非侵入性评分。

局限性

  • 研究为单中心回顾性数据的前瞻性分析,样本量有限(104例),结论需外部验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: To study the diagnostic accuracy and utility of triphasic abdominal computed tomography (CT) in the diagnosis and grading of oesophageal varices (OVs) as an alternative to endoscopy during the COVID-19 pandemic.

MATERIALS AND METHODS: A prospective analysis was undertaken of retrospective data from cirrhotic patients who underwent oesophago-gastro-duodenoscopy (OGD) and a triphasic abdominal CT from January to December 2019. Endoscopists and radiologists provided their respective independent assessment of OV grading after being blinded to the clinical details. Performance of CT grading of OVs was compared with the reference standard endoscopic grading using weighted kappa (k). Non-invasive scores such, as aspartate transaminase (AST)-to-platelet ratio index (APRI), Fibrosis-4 (FIB-4) Index, platelet: spleen (PS) ratio were correlated between the two techniques.

RESULTS: OV grading between endoscopists and radiologists showed 81.73% agreement (85 out of 104 patients) in the comparative analysis of 104 cirrhotic patients, of which no varices (57.1%, n=4), small (85.1%, n=23), medium (72.2%%, n=26), and large varices (94.1%, n=32) with a weighted k score of 0.88 (95% confidence interval 0.82-0.94). Overall, the sensitivity of CT in the diagnosis of no, small, medium, and large OVs was 66.6%, 79.3%, 89.6%, and 94.1%, respectively, with an area under the receiver operating curve (AUROC) score of 0.775, 0.887, 0.839, and 0.914. Performance of APRI, FIB-4, and PS ratio correlated well with the severity of OVs with no difference between OGD and CT grading.

CONCLUSION: Triphasic abdominal CT can be an invaluable tool in the diagnosis and grading of OVs during the COVID-19 pandemic.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Jothimani D, Danielraj S, Nallathambi B, et al. Optimal diagnostic tool for surveillance of oesophageal varices during COVID-19 pandemic. Clin Radiol. 2021. PMID: 33820640. doi:10.1016/j.crad.2021.02.029

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。