文献速递腹部外周血管USCT

多普勒超声诊断肝移植后肝动脉狭窄的准确性

Diagnostic accuracy of Doppler ultrasound for detecting hepatic artery stenosis after liver transplantation.
PubMed 文献 · Clin Radiol · 2021-04-24

本研究以CTA为参考标准,回顾性分析50例肝移植受者的多普勒超声参数,评估其对肝动脉狭窄(HAS)的诊断价值。结果显示,肝内动脉阻力指数(IHARI)和收缩期加速时间(IHASAT)联合预测模型诊断准确性良好,AUC达0.930,敏感度93.3%,特异度88%。该模型有望用于肝移植术后HAS的无创监测,但需外部验证。

要点

  • IHARI和IHASAT联合模型诊断HAS的AUC为0.930,敏感度93.3%,特异度88%。
  • IHARI截断值0.585时,敏感度86.7%,特异度85.4%,AUC 0.913。
  • IHASAT截断值0.045秒时,敏感度80%,特异度91.4%,AUC 0.857。
英文原文(摘要)· 点击展开

AIM: To evaluate the diagnostic accuracy of Doppler ultrasound (DUS) in detecting hepatic artery stenosis (HAS) after liver transplantation using computed tomography angiography (CTA) as the reference standard.

MATERIALS AND METHODS: This study included data from January 2005 to November 2017, where DUS of the hepatic artery of living and deceased donor liver grafts were compared with the reference standard, CTA. DUS parameters, such as intrahepatic artery (IHA) peak systolic velocity (PSV), resistive index (RI), systolic acceleration time (SAT); and extrahepatic artery (EHA) PSV were taken. The optimum cut-off was estimated using area under the receiver operating characteristic curve (AUC). Multivariable logistic regression analysis was developed to predict HAS.

RESULTS: Ninety-nine liver transplant cases were retrieved, 50 met the inclusion criteria where nine patients had significant HAS. HAS patients had a significantly low IHAPSV with a cut-off of 35.1 cm/s (sensitivity 53.8%, specificity 78.4%, AUC 0.701). IHARI had a significantly low RI with a cut-off 0.585 (sensitivity 86.7%, specificity 85.4%, AUC 0.913). The IHASAT cut-off was 0.045 seconds (sensitivity 80%, specificity 91.4%, AUC 0.857). The EHAPSV cut-off was 197.4 cm/s (sensitivity 50%, specificity 99.1%, AUC 0.648). The prediction model using DUS parameters IHARI and IHASAT demonstrated good discrimination with an AUC of 0.930 (95% CI: 0.843, 1.000; sensitivity 93.3%, specificity 88%).

CONCLUSION: A prediction model using the DUS parameters IHARI and IHASAT showed good diagnostic accuracy of 88.6% for monitoring liver transplant patients. If validated externally, this DUS model could be utilised to diagnose HAS in liver transplant recipients.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Mohamed Afif A, Anthony APM, Jamaruddin S, et al. Diagnostic accuracy of Doppler ultrasound for detecting hepatic artery stenosis after liver transplantation. Clin Radiol. 2021. PMID: 33902885. doi:10.1016/j.crad.2021.02.032

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。