文献速递泌尿生殖腹部MR

前列腺影像与数据报告系统第2版作为放射学性能指标:18名腹部放射科医师分析

Prostate Imaging and Data Reporting System Version 2 as a Radiology Performance Metric: An Analysis of 18 Abdominal Radiologists.
PubMed 文献 · J Am Coll Radiol · 2021-04-10

本研究为单中心质量保证回顾性队列研究,评估了18名腹部亚专科放射科医师对5556例前列腺MRI的PI-RADS v2阳性预测值(PPV)的分散度。结果显示,对于解读至少30例且有参考标准的医师,PI-RADS 3、4、5的中位PPV分别为22.1%、49.2%、81.8%,系统水平PPV分别为20.0%、48.5%、80.1%。结论认为,不同经验的腹部放射科医师可获得一致的PI-RADS v2 PPV,可用于质量保证基准。

要点

  • PI-RADS v2 评分3、4、5的系统水平PPV分别为20.0%、48.5%、80.1%。
  • 医师间PI-RADS 3的PPV变异较大(Q1-Q3:10.0%-28.6%),4和5较一致。
  • 该数据可用于放射科医师PI-RADS v2报告的质量保证基准。

局限性

  • 单中心回顾性研究,结果外推需谨慎。
  • 部分医师解读病例数较少(仅13名医师解读至少30例有参考标准)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To determine expected trained provider performance dispersion in Prostate Imaging and Data Reporting System version 2 (PI-RADS v2) positive predictive values (PPVs).

METHODS: This single-center quality assurance retrospective cohort study evaluated 5,556 consecutive prostate MRIs performed on 4,593 patients. Studies were prospectively interpreted from October 8, 2016, to July 31, 2020, by 18 subspecialty-trained abdominal radiologists (1-22 years' experience; median MRIs per radiologist: 232, first-to-third quartile range [Q1-Q3]: 128-440; 13 interpreted at least 30 MRIs with a reference standard). Maximum prospectively reported whole-gland PI-RADS v2 score was compared to post-MRI biopsy histopathology obtained within 2 years. The primary outcome was PPV of MRI by provider stratified by maximum whole-gland PI-RADS v2 score.

RESULTS: Median provider-level PPVs for the radiologists who interpreted ≥30 MRIs with a reference standard were PI-RADS 3 (22.1%; Q1-Q3: 10.0%-28.6%), PI-RADS 4 (49.2%; Q1-Q3: 41.4%-50.0%), PI-RADS 5 (81.8%; Q1-Q3: 77.1%-84.4%). Overall, the maximum whole-gland PI-RADS v2 score was PI-RADS 1 to 2 (34.6% [1,925]), PI-RADS 3 (8.5% [474]), PI-RADS 4 (21.0% [1,166]), PI-RADS 5 (18.3% [1,018]), no PI-RADS score (17.5% [973]). System-level (all providers) PPVs for maximum PI-RADS v2 scores were 20.0% (95% confidence interval [CI]: 15.7%-24.9%) for PI-RADS 3, 48.5% (95% CI: 44.8%-52.2%) for PI-RADS 4, and 80.1% for PI-RADS 5 (95% CI: 75.7%-83.9%).

CONCLUSION: Subspecialty-trained abdominal radiologists with a wide range of experience can obtain consistent positive predictive values for PI-RADS v2 scores of 3 to 5. These data can be used for quality assurance benchmarking.

来源:J Am Coll Radiol,查看原文。版权归原作者所有。

引用

  1. Davenport MS, Downs E, George AK, et al. Prostate Imaging and Data Reporting System Version 2 as a Radiology Performance Metric: An Analysis of 18 Abdominal Radiologists. J Am Coll Radiol. 2021. PMID: 33848507. doi:10.1016/j.jacr.2021.02.032

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。