双层双能CT表征肾上腺结节:虚拟平扫能否替代真实平扫?
回顾性纳入66例疑肾上腺病变患者的三期双层双能CT,由静脉期生成虚拟平扫。虚拟平扫高估肾上腺结节衰减(20.0±17.2 vs 7.1±19.8 HU,P<0.05)。以≤10 HU诊断富脂腺瘤敏感度仅0.2、特异度1.0,调整阈值≤22 HU后敏感度0.82、特异度0.85。
要点
- 虚拟平扫高估肾上腺结节及多数腹部组织衰减,直接套用10 HU阈值会漏诊富脂腺瘤。
- 若用虚拟平扫,可考虑调整阈值至≤22 HU,但特异度下降、需进一步验证。
- 腹主动脉衰减在虚拟平扫与真实平扫间无显著差异(P=0.11),可作为参考。
关键影像表现/征象
- 虚拟平扫上肾上腺结节平均衰减为20.0±17.2 HU,显著高于真实平扫的7.1±19.8 HU(P<0.05)。
- 除腹主动脉外(P=0.11),所有纳入腹部组织在虚拟平扫上的衰减均显著高于真实平扫。
诊断标准与关键数值
- 基于虚拟平扫衰减≤10 HU诊断富脂腺瘤的敏感度/特异度为0.2/1.0。
- 调整阈值≤22 HU时诊断富脂腺瘤的敏感度/特异度为0.82/0.85。
临床应用与阅片要点
- 日常阅片不宜将虚拟平扫直接等同于真实平扫,尤其评估肾上腺结节富脂性时需警惕衰减高估。
- 若以虚拟平扫替代平扫,应注明所用阈值(如≤22 HU),并提示特异度下降的可能。
局限性
- 调整阈值≤22 HU为探索性结果,作者明确指出尚需进一步验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To investigate the diagnostic performance of dual-layer dual-energy CT (dlDECT) in the evaluation of adrenal nodules.
METHODS: In this retrospective study, 66 patients with triphasic dlDECT (unenhanced, venous phase (VP), delayed phase (DP)) for suspected adrenal lesions were included. Virtual unenhanced images (VUE) were derived from VP acquisitions. Reference diagnoses were established with true unenhanced (TUE) attenuation, absolute washout, follow-up imaging and pathological data. Attenuation for adrenal lesions and abdominal tissues was acquired on TUE, VUE, VP and DP images. VUE and TUE attenuation were compared in all included tissues. Characterization of adrenal nodules based on TUE and VUE attenuation was investigated. ROC analysis was used to determine an adjusted threshold for diagnosing lipid-rich adenomas.
RESULTS: Seventy-three adrenal nodules (mean size: 18.9 ± 8.9 mm) were identified in 66 patients (38 females, 28 males; age: 61 ± 13 years) including adenoma (n = 65), metastases (n = 2), pheochromocytoma (n = 3), adrenocortical carcinoma (n = 1) and myelolipoma (n = 2). Mean attenuation of all included tissues except for the abdominal aorta (p = 0.11) was significantly higher in VUE compared to TUE images, including the attenuation of adrenal nodules (20.0 ± 17.2 vs. 7.1 ± 19.8; p < 0.05). Classification of adrenal adenomas as lipid-rich based on VUE attenuation ≤ 10 HU yielded a sensitivity/specificity of 0.2/1.0, while an adjusted threshold of ≤ 22 HU yielded a sensitivity/specificity of 0.82/0.85.
CONCLUSION: dlDECT-derived VUE images overestimated attenuation in adrenal nodules, resulting in low sensitivity for diagnosis of lipid-rich adenomas using the established 10 HU threshold. Based on an adjusted threshold (≤ 22 HU) a higher sensitivity was attained, yet at the expense of a lower specificity, warranting further validation.
引用
- Cao J, Lennartz S, Parakh A, et al. Dual-layer dual-energy CT for characterization of adrenal nodules: can virtual unenhanced images replace true unenhanced acquisitions? Abdom Radiol (NY). 2021. PMID: 33829304. doi:10.1007/s00261-021-03062-3
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。