文献速递心血管MR

自由呼吸运动校正单次激发相敏反转恢复延迟钆增强成像:肥厚型心肌病患者图像质量的前瞻性研究

Free-Breathing Motion-Corrected Single-Shot Phase-Sensitive Inversion Recovery Late-Gadolinium-Enhancement Imaging: A Prospective Study of Image Quality in Patients with Hypertrophic Cardiomyopathy.
PubMed 文献 · Korean J Radiol · 2021-04-01

该前瞻性研究纳入30例肥厚型心肌病患者,在3T MR上随机采集自由呼吸运动校正单次激发LGE(moco-ss-LGE)与屏气单次激发LGE(bh-ss-LGE)图像。结果显示moco-ss-LGE的图像质量评分和瘢痕对比噪声比均显著优于bh-ss-LGE,而三种方法测量的瘢痕大小无显著差异。提示运动校正平均化可在自由呼吸下获得更优的单次激发LGE图像质量与CNR。

要点

  • 自由呼吸moco-ss-LGE图像质量评分(4.55±0.55)显著高于屏气bh-ss-LGE(3.68±0.45,p<0.001)。
  • moco-ss-LGE的瘢痕与远隔心肌、瘢痕与左心室腔、左心室腔与远隔心肌CNR均显著高于bh-ss-LGE。
  • 三种量化方法测量的心肌瘢痕大小在两种序列间无显著差异,可互换用于瘢痕定量。

局限性

  • 单中心前瞻性研究,样本量较小(30例)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: Motion-corrected averaging with a single-shot technique was introduced for faster acquisition of late-gadolinium-enhancement (LGE) cardiovascular magnetic resonance (CMR) imaging while free-breathing. We aimed to evaluate the image quality (IQ) of free-breathing motion-corrected single-shot LGE (moco-ss-LGE) in patients with hypertrophic cardiomyopathy (HCM).

MATERIALS AND METHODS: Between April and December 2019, 30 patients (23 men; median age, 48.5; interquartile range [IQR], 36.5-61.3) with HCM were prospectively enrolled. Breath-held single-shot LGE (bh-ss-LGE) and free-breathing moco-ss-LGE images were acquired in random order on a 3T MR system. Semi-quantitative IQ scores, contrast-to-noise ratios (CNRs), and quantitative size of myocardial scar were assessed on pairs of bh-ss-LGE and moco-ss-LGE. The mean ± standard deviation of the parameters was obtained. The results were compared using the Wilcoxon signed-rank test.

RESULTS: The moco-ss-LGE images had better IQ scores than the bh-ss-LGE images (4.55 ± 0.55 vs. 3.68 ± 0.45, p < 0.001). The CNR of the scar to the remote myocardium (34.46 ± 11.85 vs. 26.13 ± 10.04, p < 0.001), scar to left ventricle (LV) cavity (13.09 ± 7.95 vs. 9.84 ± 6.65, p = 0.030), and LV cavity to remote myocardium (33.12 ± 15.53 vs. 22.69 ± 11.27, p < 0.001) were consistently greater for moco-ss-LGE images than for bh-ss-LGE images. Measurements of scar size did not differ significantly between LGE pairs using the following three different quantification methods: 1) full width at half-maximum method; 23.84 ± 12.88% vs. 24.05 ± 12.81% (p = 0.820), 2) 6-standard deviation method, 15.14 ± 10.78% vs. 15.99 ± 10.99% (p = 0.186), and 3) 3-standard deviation method; 36.51 ± 17.60% vs. 37.50 ± 17.90% (p = 0.785).

CONCLUSION: Motion-corrected averaging may allow for superior IQ and CNRs with free-breathing in single-shot LGE imaging, with a herald of free-breathing moco-ss-LGE as the scar imaging technique of choice for clinical practice.

来源:Korean J Radiol,查看原文。版权归原作者所有。

引用

  1. Cha MJ, Cho I, Hong J, et al. Free-Breathing Motion-Corrected Single-Shot Phase-Sensitive Inversion Recovery Late-Gadolinium-Enhancement Imaging: A Prospective Study of Image Quality in Patients with Hypertrophic Cardiomyopathy. Korean J Radiol. 2021. PMID: 33856138. doi:10.3348/kjr.2020.1296

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。