三尖瓣环收缩期位移在功能性心脏CT中评估右心室功能并与MRI对照
结果显示CT-TAPSE与MR-RVEF及CT-RVEF均呈中度相关,乘数因子2.7时Bland-Altman偏倚最低(0.74%)。结论认为CT-TAPSE是易于获取的右心室功能参数,可作为快速验证CT右心室容积分析及估算MR-RVEF的辅助工具。
要点
- CT-TAPSE与MR-RVEF中度相关(r=0.58),可作为快速验证CT右心室容积分析的辅助指标。
- CT-TAPSE与CT-RVEF相关性稍高(r=0.63),有助于日常CT报告中对右心室功能的快速评估。
- Bland-Altman分析提示CT-TAPSE乘以2.7时与MR-RVEF偏倚最低(0.74%),但需注意该乘数因子的适用条件。
关键影像表现/征象
- MR-TAPSE定义为四腔心CINE序列上舒张末期和收缩末期从三尖瓣环侧缘至右心室心尖的两条参考线长度之差,CT-TAPSE在四腔心重组图像上以类似方式测定。
- CT-TAPSE与MR-RVEF呈中度相关(r=0.58,p<0.001),与CT-RVEF亦呈中度相关(r=0.63,p<0.001)。
- MR-TAPSE与MR-RVEF呈中度相关(r=0.57,p<0.001)。
诊断标准与关键数值
- CT-TAPSE与MR-RVEF的Bland-Altman分析中,采用乘数因子2.7时偏倚最低(0.74%)。
- MR-TAPSE与MR-RVEF的相关系数r=0.57(p<0.001);CT-TAPSE与MR-RVEF的相关系数r=0.58(p<0.001);CT-TAPSE与CT-RVEF的相关系数r=0.63(p<0.001)。
临床应用与阅片要点
- 在日常心脏CT阅片时,可于四腔心重组图像上快速测量TAPSE,作为右心室容积分析结果的快速交叉验证。
- CT-TAPSE与MR-RVEF仅呈中度相关,不宜单独作为右心室功能分级的唯一依据,需结合容积法RVEF综合判断。
- 采用乘数因子2.7将CT-TAPSE换算为MR-RVEF估计值时,需注意该因子来自小样本研究,外推需谨慎。
局限性
- CT右心室容积采用自动软件处理,MRI采用手动Simpson法,处理方式不同可能影响结果比较。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIM: To compare ejection fraction estimated by tricuspid annular plane systolic excursion (TAPSE) using cardiac computed tomography (CT) and cardiac magnetic resonance imaging (MRI) to the non-invasive reference standard, volumetric quantification of right ventricular ejection fraction (RVEF) by cardiac magnetic resonance imaging (MRI).
MATERIALS AND METHODS: Thirty-one patients, who had undergone functional cardiac CT angiogram and cardiac MRI within 12 months, were evaluated retrospectively. Right ventricular (RV) volumes were processed using automated cardiac analysis software for CT, and manually processed by Simpson's method for MRI. MR-TAPSE was defined as the difference in length between two separate reference lines drawn at end diastole and end systole from the lateral tricuspid annulus to the right ventricular apex measured on four-chamber CINE images. CT-TAPSE was determined in an analogous manner on four-chamber reformatted images.
RESULTS: MR-TAPSE correlated moderately with MR-RVEF, (r=0.57, p<0.001). CT-TAPSE was found to correlate moderately well with MR-RVEF (r=0.58, p<0.001) and CT-RVEF (r=0.63, p<0.001). Bland-Altman analysis repeated with various multiplication factors for CT-TAPSE and MR-RVEF, determined a multiplication factor of 2.7 resulted in the lowest bias (0.74%).
CONCLUSION: CT-TAPSE is an easily obtainable parameter of RV function and is correlated with CT-RVEF and MR-RVEF. It can function as a quick check to rapidly validate CT right volumetry and estimate MR-RVEF.
引用
- Newman K, Wilson R, Roberts JM, et al. Tricuspid annular plane systolic excursion for the evaluation of right ventricular function in functional cardiac CT compared to MRI. Clin Radiol. 2021. PMID: 33879320. doi:10.1016/j.crad.2021.02.018
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。