多普勒超声半自动测量动脉僵硬度:临床可行性与重复性研究
本研究提出一种半自动测量主动脉脉搏波传导速度(PWV)的新方法,在50例疑似冠心病患者中由三名观察者(含一名无超声经验的心脏科医生)测量颈-股PWV(cfPWV)。半自动法cfPWVA与两名有经验超声医师手动法均值cfPWVM一致性极佳(ICC 0.915),无经验观察者测量值与cfPWVM无差异(8.04±1.29 vs 8.14±1.32 m/s,p>0.05),且耗时显著缩短(122±35 s vs 455±105 s,p<0.0001),节省约73%时间。
要点
- 半自动cfPWV测量与有经验医师手动法一致性高(ICC 0.915),无经验操作者也可获得可靠结果。
- 新方法耗时122±35 s,较手动法455±105 s节省约73%时间,适合临床常规开展。
- 无经验观察者测得cfPWVA与cfPWVM无显著差异,ICC 0.877,提示学习曲线短。
局限性
- 单中心研究,样本量50例,结论外推需多中心验证。
- 参考标准为手动法均值而非金标准,可能存在参考方法本身误差。
- 研究对象为疑似冠心病患者,未在健康人群或其他疾病人群中验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
The conventional manual approach to measurement of aortic pulse wave velocity (PWV) by Doppler ultrasonography is time consuming and operator dependent. Here we report a new semi-automated methodology for more efficient and objective measurement of aortic PWV and results of tests of its clinical feasibility and reproducibility. Carotid-femoral pulse wave velocity (cfPWV) was measured in 50 patients with suspected coronary artery disease (aged 59.2 ± 10.0 y, 36 males) by three independent observers, including two experienced sonographers and one cardiologist without ultrasonographic experience. The cfPWV measured by the semi-automatic method (cfPWVA) was compared with reference values obtained by averaging measurements by two experienced sonographers using the conventional standard manual method (cfPWVM). Measurements of cfPWVA were feasible in all 50 patients and exhibited excellent agreement with averaged cfPWVM from the two experienced sonographers, with an intraclass correlation coefficient (ICC) of 0.915 (95% confidence interval: 0.876-0.942). The inexperienced observer-measured cfPWVA did not differ from the cfPWVM measured by the two experienced sonographers (8.04 ± 1.29 vs. 8.14 ± 1.32 m/s, p > 0.05), with a high consistency by ICC of 0.877 (0.793-0.928). Bland-Altman plots further illustrated the good agreement between the two methods and good intra- and inter-observer reproducibility. Time consumption for cfPWV measurement using the new method was significantly less than that for the manual method (122 ± 35 s vs. 455 ± 105 s, p < 0.0001), saving about 73% of the time. This new semi-automatic methodology for aortic PWV measurement not only has an accuracy similar to that of the conventional standard manual method but is also highly feasible and time saving. It may provide a reliable, simple and reproducible approach to arterial stiffness evaluation in clinical settings.
引用
- Wang Z, Wang D, Han M, et al. A Novel Methodology for Semi-automatic Measurement of Arterial Stiffness by Doppler Ultrasound: Clinical Feasibility and Reproducibility. Ultrasound Med Biol. 2021. PMID: 33858722. doi:10.1016/j.ultrasmedbio.2021.03.004
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。