弥散加权成像中导航触发与自由呼吸采集对肝脏小病灶检出及图像质量的比较
NT在肝脏边缘勾画、血管锐利度及小病灶(<1 cm)显示上更优,FB对心脏运动伪影控制更好;两者对大病灶(≥1 cm)显示及整体图像质量差异不大。作者据此推荐使用NT。
要点
- 小病灶(<1 cm)检出优选NT,大病灶FB与NT效果相当。
- NT图像肝脏边缘与血管更锐利,FB心脏运动伪影更轻。
- b800时NT的病灶SNR为41.5、FB为38.4,肝脏SNR分别为16.8与19.8。
核心结论
- NT可提高小局灶性肝脏病灶(<1 cm)的检出,对大病灶(≥1 cm)FB与NT检出效果相近,作者推荐采用NT。
研究设计与样本
- 采用自旋回波EPI-DWI,NT与FB两种采集方式,b值为50与800 s/mm²,两者采集时间相近。
- 由2名阅片者独立分析,参考标准为两种采集方式间可见病灶数的比较。
关键影像表现/征象
- NT在肝脏边缘勾画与血管锐利度方面优于FB。
- FB对心脏运动伪影严重程度的控制优于NT。
- 阶梯状伪影、整体图像质量及大病灶(≥1 cm)显示亮度两者差异不大。
- 小病灶(<1 cm)显示亮度以NT更佳。
诊断标准与关键数值
- 小病灶(<1 cm):b800时两名阅片者均报告NT在11例中发现更多病灶。
- 大病灶(≥1 cm):b800时仅1名阅片者在1例中报告NT发现更多病灶。
- b800时NT/FB的肝脏与病灶平均SNR分别为16.8/41.5与19.8/38.4。
临床应用与阅片要点
- 报告小病灶时应考虑采用NT采集,以降低<1 cm病灶漏检风险。
- FB图像需注意心脏运动伪影对肝左叶及邻近区域判读的影响。
- 解读时应结合边缘勾画与伪影分布判断病灶真实性。
局限性
- 仅纳入非肝硬化患者,结论不适用于肝硬化背景。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: The aim of this study was to compare intraindividual diffusion-weighted imaging (DWI) of the liver acquired with free breathing (FB) versus navigator triggering (NT) for assessing small focal liver lesions (FLLs) in noncirrhotic patients.
MATERIALS AND METHODS: Patients with known or suspected multiple FLLs were prospectively included, and spin-echo echo-planar DWI with NT and FB acquisition was performed (b-values, 50 and 800 s/mm2 [b50 and b800]). NT and FB DWI sequences with similar acquisitions times were used. Liver and lesion signal-to-noise ratios were measured at b800. The DWI scans were analyzed independently by 2 readers. Liver edge delineation, presence of stair-step artifacts, vessel sharpness, severity of cardiac motion artifacts, overall image quality, and lesion conspicuity were rated with 5-point Likert scales. Small and large FLLs (ie, <1 cm or ≥1 cm) were rated separately for lesion conspicuity. The FLL detectability was estimated by comparing the number of lesions visible with FB to those visible with NT.
RESULTS: Forty-three patients were included in the study. The FB acquisition performed better in terms of severity of cardiac motion artifacts. The NT performed better in terms of liver edge delineation and vessel sharpness. Little difference was found for stair-step artifact, overall image quality, and conspicuity of large FLL, whereas the conspicuity of small FLL was better for NT. For small FLL, both readers found more lesions with NT in 11 cases at b800. For large FLL, this effect was much less pronounced (1 case at b800 reported by 1 of the readers). The mean liver and lesion signal-to-noise ratios were 16.8/41.5 and 19.8/38.4 for NT/FB, respectively.
CONCLUSIONS: Small FLL detection is better with NT. Large FLL detection by FB and NT is similarly good. We conclude that NT should be used.