文献速递心血管MR

三维超快心脏磁共振协议(含单次屏气三维序列)的临床验证

Clinical Validation of a 3-Dimensional Ultrafast Cardiac Magnetic Resonance Protocol Including Single Breath-Hold 3-Dimensional Sequences.
PubMed 文献 · JACC Cardiovasc Imaging · 2021-04-14

前瞻性纳入107例患者,比较三维ESSOS电影和三维LGE序列与标准二维电影+LGE协议。三维序列采集仅24秒和22秒,左心室射血分数一致性ICC为0.96,右心室射血分数ICC为0.73,三维LGE观察者内和观察者间一致性优秀。联合协议可在1分钟内完成完整心脏检查。

要点

  • 三维ESSOS电影序列单次屏气采集24秒,可定量左心室和右心室功能,左心室射血分数与二维一致性优秀。
  • 三维LGE序列单次屏气采集22秒,与二维LGE一致性优秀,观察者内和观察者间一致性优秀。
  • 联合三维电影和三维LGE协议可在1分钟内完成完整心脏磁共振检查,图像质量良好且所有病例均可定量。

关键影像表现/征象

  • 三维ESSOS和三维LGE图像质量良好,所有病例均可进行定量分析。
  • 三维LGE观察者内和观察者间一致性优秀。

诊断标准与关键数值

  • 左心室射血分数三维与二维分别为51±12%和52±12%,组间一致性ICC为0.96(95%CI 0.94-0.97),偏倚不显著。
  • 右心室射血分数三维与二维分别为60.4±5.4%和59.7±5.2%,组间一致性ICC为0.73(95%CI 0.63-0.81),偏倚不显著。
  • 三维与二维LGE一致性优秀。

临床应用与阅片要点

  • 三维ESSOS电影序列可用于单次屏气下定量左心室质量、容积及左右心室射血分数。
  • 三维LGE序列可用于评估延迟强化,观察者内和观察者间一致性优秀。
  • 联合协议可缩短检查时间至1分钟内,扩展心脏磁共振适应证并提高患者舒适度。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: This study sought to clinically validate a novel 3-dimensional (3D) ultrafast cardiac magnetic resonance (CMR) protocol including cine (anatomy and function) and late gadolinium enhancement (LGE), each in a single breath-hold.

BACKGROUND: CMR is the reference tool for cardiac imaging but is time-consuming.

METHODS: A protocol comprising isotropic 3D cine (Enhanced sensitivity encoding [SENSE] by Static Outer volume Subtraction [ESSOS]) and isotropic 3D LGE sequences was compared with a standard cine+LGE protocol in a prospective study of 107 patients (age 58 ± 11 years; 24% female). Left ventricular (LV) mass, volumes, and LV and right ventricular (RV) ejection fraction (LVEF, RVEF) were assessed by 3D ESSOS and 2D cine CMR. LGE (% LV) was assessed using 3D and 2D sequences.

RESULTS: Three-dimensional and LGE acquisitions lasted 24 and 22 s, respectively. Three-dimensional and LGE images were of good quality and allowed quantification in all cases. Mean LVEF by 3D and 2D CMR were 51 ± 12% and 52 ± 12%, respectively, with excellent intermethod agreement (intraclass correlation coefficient [ICC]: 0.96; 95% confidence interval [CI]: 0.94 to 0.97) and insignificant bias. Mean RVEF 3D and 2D CMR were 60.4 ± 5.4% and 59.7 ± 5.2%, respectively, with acceptable intermethod agreement (ICC: 0.73; 95% CI: 0.63 to 0.81) and insignificant bias. Both 2D and 3D LGE showed excellent agreement, and intraobserver and interobserver agreement were excellent for 3D LGE.

CONCLUSIONS: ESSOS single breath-hold 3D CMR allows accurate assessment of heart anatomy and function. Combining ESSOS with 3D LGE allows complete cardiac examination in <1 min of acquisition time. This protocol expands the indication for CMR, reduces costs, and increases patient comfort.

来源:JACC Cardiovasc Imaging,查看原文。版权归原作者所有。

引用

  1. Gómez-Talavera S, Fernandez-Jimenez R, Fuster V, et al. Clinical Validation of a 3-Dimensional Ultrafast Cardiac Magnetic Resonance Protocol Including Single Breath-Hold 3-Dimensional Sequences. JACC Cardiovasc Imaging. 2021. PMID: 33865783. doi:10.1016/j.jcmg.2021.02.031

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。