文献速递儿科影像腹部胸部CT

韩国基于体重和体径建立儿童腹部盆腔及胸部CT本地诊断参考水平

Establishment of Local Diagnostic Reference Levels of Pediatric Abdominopelvic and Chest CT Examinations Based on the Body Weight and Size in Korea.
PubMed 文献 · Korean J Radiol · 2021-04-01

该研究分析了韩国7家大学医院2017年全年2494例15岁及以下儿童的腹部盆腔和胸部CT检查剂量,按体重和有效直径分组,以各机构典型值分布的75百分位建立本地诊断参考水平(DRL)。结果显示按体重和体径分组的CTDIvol和SSDE DRL值,且本地DRL低于既往调查和其他国家DRL。

要点

  • 儿童CT剂量报告应结合体重和体径分组评估,而非仅按年龄。
  • 本地DRL以各机构典型值75百分位设定,可作为剂量优化参考。
  • SSDE在所有年龄组均高于CTDIvol,报告时需注意两者差异。

核心结论

  • 研究建立了韩国儿童腹部盆腔和胸部CT基于体重和体径的本地DRL,本地DRL低于既往剂量调查和其他国家DRL。

研究设计与样本

  • 按体重和有效直径分组,DRL设定为各机构典型值分布的75百分位。

诊断标准与关键数值

  • 体重5、15、30、50、80 kg时,腹部盆腔CT的CTDIvol DRL分别为1.4、2.2、2.7、4.0、4.7 mGy,胸部CT分别为1.2、1.5、2.3、3.7、5.8 mGy。
  • 有效直径<13 cm、14-16 cm、17-20 cm、21-24 cm、>24 cm时,腹部盆腔CT的SSDE DRL分别为4.1、5.0、5.7、7.1、7.2 mGy,胸部CT分别为2.8、4.6、4.3、5.3、7.5 mGy。
  • SSDE在所有年龄组均大于CTDIvol。

临床应用与阅片要点

  • 儿童CT剂量评估可参照按体重和体径分组的本地DRL,关注SSDE与CTDIvol的差异。
  • 报告剂量信息时可结合体重或体径分组,便于与参考水平比较。

局限性

  • 研究仅纳入7家大学医院,需更多机构和检查以制定国家DRL并更新当前DRL。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: The purposes of this study were to analyze the radiation doses for pediatric abdominopelvic and chest CT examinations from university hospitals in Korea and to establish the local diagnostic reference levels (DRLs) based on the body weight and size.

MATERIALS AND METHODS: At seven university hospitals in Korea, 2494 CT examinations of patients aged 15 years or younger (1625 abdominopelvic and 869 chest CT examinations) between January and December 2017 were analyzed in this study. CT scans were transferred to commercial automated dose management software for the analysis after being de-identified. DRLs were calculated after grouping the patients according to the body weight and effective diameter. DRLs were set at the 75th percentile of the distribution of each institution's typical values.

RESULTS: For body weights of 5, 15, 30, 50, and 80 kg, DRLs (volume CT dose index [CTDIvol]) were 1.4, 2.2, 2.7, 4.0, and 4.7 mGy, respectively, for abdominopelvic CT and 1.2, 1.5, 2.3, 3.7, and 5.8 mGy, respectively, for chest CT. For effective diameters of < 13 cm, 14-16 cm, 17-20 cm, 21-24 cm, and > 24 cm, DRLs (size-specific dose estimates [SSDE]) were 4.1, 5.0, 5.7, 7.1, and 7.2 mGy, respectively, for abdominopelvic CT and 2.8, 4.6, 4.3, 5.3, and 7.5 mGy, respectively, for chest CT. SSDE was greater than CTDIvol in all age groups. Overall, the local DRL was lower than DRLs in previously conducted dose surveys and other countries.

CONCLUSION: Our study set local DRLs in pediatric abdominopelvic and chest CT examinations for the body weight and size. Further research involving more facilities and CT examinations is required to develop national DRLs and update the current DRLs.

来源:Korean J Radiol,查看原文。版权归原作者所有。

引用

  1. Hwang JY, Choi YH, Yoon HM, et al. Establishment of Local Diagnostic Reference Levels of Pediatric Abdominopelvic and Chest CT Examinations Based on the Body Weight and Size in Korea. Korean J Radiol. 2021. PMID: 33856132. doi:10.3348/kjr.2020.0890

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。