文献速递胸部CT

血管相关结构预测非IPF型CT表现者的UIP病理

Vessel-related structures predict UIP pathology in those with a non-IPF pattern on CT.
PubMed 文献 · Eur Radiol · 2021-04-13

研究纳入有外科肺活检和胸部CT的间质性肺病患者,用CALIPER定量分析血管相关结构(VRS)等变量,发现仅VRS与病理UIP独立相关,VRS截断值173 cm3时敏感度55.9%、特异度80.4%,在非IPF诊断CT类别中可区分病理UIP。

要点

  • VRS是预测病理UIP的独立定量指标,截断值173 cm3。
  • VRS>173 cm3者病理UIP比例84.2%,接近定性 probable UIP 的88.9%。
  • VRS的鉴别价值主要见于非IPF诊断CT类别。

核心结论

  • CALIPER定量的VRS体积与病理UIP独立相关,可作为CT预测间质性肺病病理的辅助指标。

研究设计与样本

  • 研究纳入多学科诊断的间质性肺病病例,要求有外科肺活检且胸部CT与活检间隔1年内。
  • 使用CALIPER程序对非增强CT进行定量分析,并与病理诊断及定性CT模式比较。

关键影像表现/征象

  • 单变量分析中网格影体积(p=0.012)、蜂窝影体积(p=0.017)和VRS体积(p<0.001)与病理UIP相关。
  • 多变量分析中仅VRS与病理UIP独立相关(p=0.013)。
  • VRS在非IPF诊断CT类别中可区分病理UIP(p<0.001),在其他定性CT模式中无此区分能力。

诊断标准与关键数值

  • VRS截断值173 cm3预测病理UIP的敏感度55.9%、特异度80.4%。
  • 标准定性CT评估预测病理UIP的敏感度60.6%、特异度80.4%。
  • VRS>173 cm3者病理UIP比例84.2%,定性 probable UIP 者病理UIP比例88.9%。

临床应用与阅片要点

  • 对CT表现为非IPF诊断类别的间质性肺病患者,可关注CALIPER定量的VRS体积辅助预测病理UIP。
  • VRS>173 cm3时病理UIP可能性接近 probable UIP,或可提示避免病理检查。

局限性

  • 原文未明确报告样本量、中心数及研究设计类型等细节。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To determine if a quantitative imaging variable (vessel-related structures [VRS]) could identify subjects with a non-IPF diagnosis CT pattern who were highly likely to have UIP histologically.

METHODS: Subjects with a multidisciplinary diagnosis of interstitial lung disease including surgical lung biopsy and chest CT within 1 year of each other were included in the study. Non-contrast CT scans were analyzed using the Computer-Aided Lung Informatics for Pathology Evaluation and Rating (CALIPER) program, which quantifies the amount of various abnormal CT patterns on chest CT. Quantitative data were analyzed relative to pathological diagnosis as well as the qualitative CT pattern.

RESULTS: CALIPER-derived volumes of reticulation (p = 0.012), honeycombing (p = 0.017), and VRS (p < 0.001) were associated with a UIP pattern on pathology on univariate analysis but only VRS was associated with a UIP pathology on multivariable analysis (p = 0.013). Using a VRS cut-off of 173 cm3, the sensitivity and specificity for pathological UIP were similar to those for standard qualitative CT assessment (55.9% and 80.4% compared to 60.6% and 80.4%, respectively). VRS differentiated pathological UIP cases in those with a non-IPF diagnosis CT category (p < 0.001) but not in other qualitative CT patterns (typical UIP, probable UIP, and indeterminate for UIP). The rate of pathological UIP in those with VRS greater than 173 cm3 (84.2%) was nearly identical to those who had a qualitative CT pattern of probable UIP (88.9%).

CONCLUSIONS: VRS may be an adjunct to CT in predicting pathology in patients with interstitial lung disease.

KEY POINTS: • Volume of vessel-related structures (VRS) was associated with usual interstitial pneumonia (UIP) on pathology. • This differentiation arose from those with CT scans with a non-IPF diagnosis imaging pattern. • Higher VRS has similar diagnostic ramifications for UIP as probable UIP, transitively suggesting in patients with high VRS, pathology may be obviated.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Chung JH, Adegunsoye A, Oldham JM, et al. Vessel-related structures predict UIP pathology in those with a non-IPF pattern on CT. Eur Radiol. 2021. PMID: 33847810. doi:10.1007/s00330-021-07861-6

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。