文献速递胸部PETCT

俯卧位[18F]FDG PET/CT减少肺结节评估中的呼吸运动伪影

Prone position [18F]FDG PET/CT to reduce respiratory motion artefacts in the evaluation of lung nodules.
PubMed 文献 · Eur Radiol · 2021-04-14

本研究回顾性纳入28例肺结节患者,对比俯卧位与仰卧位[18F]FDG PET/CT,发现俯卧位可提高SUVmax、降低MTV、缩短PET与CT膈肌位置差,并减少配准不良;视觉分析中恶性结节在俯卧位阳性率更高。

要点

  • 俯卧位PET/CT可减少呼吸运动导致的模糊和配准不良
  • 俯卧位下肺结节SUVmax更高、MTV更低,测量更精确
  • 对仰卧位视觉阴性但怀疑恶性的结节,俯卧位可能帮助正确判读

关键影像表现/征象

  • 俯卧位较仰卧位SUVmax显著更高(p=0.043)、MTV更低(p=0.007)、PET与CT膈肌位置差更短(p=0.021)。
  • 配准不良发生率仰卧位53.6%、俯卧位28.6%(p=0.092);仰卧位配准不良的15例中,10例(66.7%)俯卧位无配准不良。
  • Dice相似系数在18/28例(64.3%)中俯卧位高于仰卧位。
  • 视觉分析:恶性结节FDG摄取阳性率俯卧位93.3% vs 良性40.0%(p=0.032),仰卧位80.0% vs 40.0%(p=0.131)。

诊断标准与关键数值

  • 视觉分析以活检病理为参考标准,评估结节FDG摄取阳性与否。
  • 定量参数包括SUVmax、MTV、PET与CT膈肌位置差(DDP)、Dice相似系数(DSC)和配准不良发生情况。

临床应用与阅片要点

  • 对下叶或呼吸运动明显的肺结节,可考虑加做俯卧位PET/CT以改善配准和定量测量。
  • 仰卧位视觉判读阴性但临床怀疑恶性时,俯卧位可能提高恶性结节检出阳性率。
  • 注意俯卧位可能改变膈肌位置和结节相对位置,需结合CT形态综合判读。

局限性

  • 回顾性单中心研究,样本量小(28例),仅20例有病理证实。
  • 配准不良发生率差异无统计学意义(p=0.092),需更大样本验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: 2-Deoxy-2-[18F]fluoro-D-glucose ([18F]FDG) positron-emission tomography/computed tomography (PET/CT) is widely used to evaluate lung nodules, although respiratory motion artefacts may occur. We investigated the value of prone position PET/CT (pPET/CT) in lung nodule evaluation compared with standard supine position PET/CT (sPET/CT).

METHODS: We retrospectively reviewed 28 consecutive patients (20 men; age, 65.6 ± 12.1 years) with a lung nodule (size, 16.8 ± 5.5 mm) located below the sub-carinal level who underwent [18F]FDG PET/CT in a standard supine position and additional prone position. The maximum standardised uptake value (SUVmax), metabolic tumour volume (MTV), difference of diaphragm position between PET and CT (DDP), Dice's similarity coefficient (DSC) and occurrence of mis-registration were analysed. The [18F]FDG uptake of 20 biopsy-confirmed (15 malignant) nodules was evaluated visually.

RESULTS: pPET/CT yielded a significantly higher SUVmax, lower MTV and shorter DDP than with sPET/CT (p = 0.043, 0.007 and 0.021, respectively). Mis-registration occurred in 53.6% of cases in sPET/CT and in 28.6% of cases in pPET/CT (p = 0.092). Among the 15 patients with mis-registration in sPET/CT, 10 patients (66.7%) did not show mis-registration in pPET/CT. DSC was higher in pPET/CT than in sPET/CT in 18 out of 28 patients (64.3%). In visual analysis, malignant nodules exhibited a higher [18F]FDG uptake positivity than benign nodules in pPET/CT (93.3% vs. 40.0%, p = 0.032) but not in sPET/CT (80.0% vs. 40.0%, p = 0.131).

CONCLUSIONS: pPET/CT reduces respiratory motion artefact and enables more-precise measurements of PET parameters.

KEY POINTS: • In prone position PET/CT, the decrease in the blurring effect caused by reduced respiratory motion resulted in a higher SUVmax and lower MTV in lung nodules than that with supine position PET/CT. • Prone position PET/CT was useful to interpret correctly malignant lung nodules as being positive in individual cases that had a negative result in supine position PET/CT.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Lee HJ, Son HJ, Yun M, et al. Prone position [18F]FDG PET/CT to reduce respiratory motion artefacts in the evaluation of lung nodules. Eur Radiol. 2021. PMID: 33852046. doi:10.1007/s00330-021-07894-x

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。