文献速递神经MR

体素内不相干运动成像鉴别高、低级别胶质瘤诊断价值的系统评价与Meta分析

The diagnostic value of intravoxel incoherent motion imaging in differentiating high-grade from low-grade gliomas: a systematic review and meta-analysis.
PubMed 文献 · Br J Radiol · 2021-01-01

该Meta分析纳入6篇文献共252例脑胶质瘤,评估IVIM参数D、D*、f鉴别高级别与低级别胶质瘤的准确性。汇总敏感度分别为0.85、0.78、0.89,特异度分别为0.78、0.68、0.88,SROC曲线AUC分别为0.89、0.81、0.94。结论认为IVIM参数具有中等或较高诊断价值,其中f参数敏感度和特异度更优。

要点

  • IVIM参数f鉴别高低级别胶质瘤的AUC达0.94,敏感度0.89、特异度0.88,诊断效能最佳。
  • D参数AUC为0.89,敏感度0.85、特异度0.78,诊断价值中等偏高。
  • D*参数AUC为0.81,敏感度0.78、特异度0.68,在三者中诊断效能相对最低。

核心结论

  • IVIM参数D、D*和f对鉴别高级别与低级别胶质瘤具有中等或较高诊断准确性,其中f参数敏感度和特异度更优。
  • 需要标准化方法学来指导该方法用于临床决策,并需更多临床研究验证。

研究设计与样本

  • 共纳入6篇文献、252例脑胶质瘤,采用QUADAS-2工具评价研究质量。
  • 合并计算IVIM参数D、D*和f的敏感度、特异度及SROC曲线下面积以评估诊断准确性。

诊断标准与关键数值

  • D参数汇总敏感度0.85(95%CI 0.76-0.91),特异度0.78(95%CI 0.60-0.90),SROC AUC 0.89(95%CI 0.86-0.92)。
  • D*参数汇总敏感度0.78(95%CI 0.71-0.85),特异度0.68(95%CI 0.56-0.79),SROC AUC 0.81(95%CI 0.77-0.84)。
  • f参数汇总敏感度0.89(95%CI 0.76-0.96),特异度0.88(95%CI 0.76-0.94),SROC AUC 0.94(95%CI 0.92-0.96)。

临床应用与阅片要点

  • 在胶质瘤术前MRI评估中可参考IVIM参数f辅助鉴别高低级别,其AUC最高但敏感度95%CI下限偏低。
  • D*参数特异度仅0.68,单独用于分级需谨慎,建议结合D和f参数综合判断。
  • 原文强调需标准化IVIM采集与后处理方法,临床解读时应关注各中心方法学差异对阈值的影响。

局限性

  • 仅纳入6篇文献、252例样本,样本量较小。
  • 原文指出需要更多临床研究来证实其观点。
  • 原文指出需要标准化方法学以指导临床决策。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: This meta-analysis was carried out for assessing the accuracy of intravoxel incoherent motion (IVIM) parameters true diffusion coefficient (D), pseudo-diffusion coefficient (D*), and perfusion fraction (f) in differentiating low-grade gliomas (LGGs) from high-grade gliomas (HGGs).

METHODS: Literatures concerning IVIM in the grading of brain gliomas published prior to October 20, 2020, searched in the Embase, PubMed, and Cochrane library. Use the quality assessment of diagnostic accuracy studies 2 (QUADAS 2) to evaluate the quality of studies. We estimated the pooled sensitivity, specificity, and the area under the summary ROC (SROC) curve to identification the accuracy of IVIM parameters D, D*, and f evaluation in grading gliomas.

RESULTS: Totally, 6 articles including 252 brain gliomas conform to the inclusion criteria. The pooled sensitivity of parameters D, D*, and f derived from IVIM were 0.85 (95%Cl, 0.76-0.91), 0.78 (95%Cl, 0.71-0.85), and 0.89 (95%Cl, 0.76-0.96), respectively. The pooled specificity were 0.78 (95%Cl, 0.60-0.90), 0.68 (95%Cl, 0.56-0.79), and 0.88 (95%Cl, 0.76-0.94), respectively. Meanwhile, the AUC of SROC curve were 0.89 (95%Cl, 0.86-0.92) , 0.81 (95%Cl, 0.77-0.84), and 0.94 (95%Cl, 0.92-0.96), respectively.

CONCLUSION: This meta-analysis suggested that IVIM parameters D, D*, and f have moderate or high diagnosis value accuracy in differentiating HGGs from LGGs, and the parameter f has greater sensitivity and specificity. Standardized methodology is warranted to guide the use of this method for clinical decision-making. However, more clinical studies are needed to prove our view.

ADVANCES IN KNOWLEDGE: IVIM parameter f showed greater sensitivity and specificity, as well as excellent performance than parameter D* and D.

来源:Br J Radiol,查看原文。版权归原作者所有。

引用

  1. Luo H, He L, Cheng W, et al. The diagnostic value of intravoxel incoherent motion imaging in differentiating high-grade from low-grade gliomas: a systematic review and meta-analysis. Br J Radiol. 2021. PMID: 33876653. doi:10.1259/bjr.20201321

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。