文献速递神经技术与安全CT

头部CT自动病理检测与患者分诊的弱监督机器学习研究

Automated Pathology Detection and Patient Triage in Routinely Acquired Head Computed Tomography Scans.
PubMed 文献 · Invest Radiol · 2021-01-01

回顾性纳入2020年3月一家三级医院连续248例首次头部CT,使用弱监督机器学习进行异常检测并分为正常、病理或不确定三类,以专家报告为参考标准。研究数据集AUC为0.95,外部验证AUC为0.87;判为正常时排除病理的阴性预测值为100%,敏感度100%、特异度86%。约三分之二扫描可获得明确分类,不确定病例中63%存在病理。

要点

  • 弱监督异常检测模型对头部CT正常与病理的区分AUC达0.95,外部验证0.87。
  • 模型判为正常时阴性预测值100%,可作为排除病理的可靠提示。
  • 约三分之一扫描被归为不确定,其中63%实际有病理,需重点复核。

核心结论

  • 弱监督异常检测系统在连续头部CT队列中约三分之二扫描可明确分类为正常或病理,诊断准确性优秀且排除病理的阴性预测值达100%。
  • 不确定分类的病例中病理比例仍较高,异常热图可为病理判读提供重要引导。

研究设计与样本

  • 回顾性研究,纳入一家三级医院2020年3月连续首次头部CT患者,最终纳入248例。
  • 采用弱监督机器学习进行异常检测,以体素级显示异常并汇总为0至1的异常评分,按阈值分为正常、病理或不确定三类。
  • 以专家验证的放射学报告及多类病理标签为参考标准,采用受试者工作特征分析评估,不确定结果在准确性分析中并入病理预测。
  • 外部验证使用公开数据集CQ500。

关键影像表现/征象

  • 异常检测以体素级异常热图形式展示,可提示病理区域。

诊断标准与关键数值

  • 异常评分范围0至1,阈值将患者分为正常、病理或不确定三类。
  • 研究数据集区分正常与病理的AUC为0.95(95%CI 0.92-0.98),外部验证AUC为0.87(95%CI 0.81-0.94)。
  • 判为正常时排除病理的阴性预测值为100%(25/25),阳性预测值为97.6%(137/141)。
  • 敏感度100%,特异度86%。

临床应用与阅片要点

  • 可将模型判为正常作为排除病理的辅助提示,但需结合临床与影像复核。
  • 对不确定分类的扫描应视为高风险,其中63%存在病理,需重点审阅异常热图提示区域。

局限性

  • 单中心回顾性研究,样本量有限,仅纳入首次头部CT。
  • 约32.7%扫描无法明确分类,不确定结果在准确性分析中并入病理可能影响测量。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: Anomaly detection systems can potentially uncover the entire spectrum of pathologies through deviations from a learned norm, meaningfully supporting the radiologist's workflow. We aim to report on the utility of a weakly supervised machine learning (ML) tool to detect pathologies in head computed tomography (CT) and adequately triage patients in an unselected patient cohort.

MATERIALS AND METHODS: All patients having undergone a head CT at a tertiary care hospital in March 2020 were eligible for retrospective analysis. Only the first scan of each patient was included. Anomaly detection was performed using a weakly supervised ML technique. Anomalous findings were displayed on voxel-level and pooled to an anomaly score ranging from 0 to 1. Thresholds for this score classified patients into the 3 classes: "normal," "pathological," or "inconclusive." Expert-validated radiological reports with multiclass pathology labels were considered as ground truth. Test assessment was performed with receiver operator characteristics analysis; inconclusive results were pooled to "pathological" predictions for accuracy measurements. External validity was tested in a publicly available external data set (CQ500).

RESULTS: During the investigation period, 297 patients were referred for head CT of which 248 could be included. Definite ratings into normal/pathological were feasible in 167 patients (67.3%); 81 scans (32.7%) remained inconclusive. The area under the curve to differentiate normal from pathological scans was 0.95 (95% confidence interval, 0.92-0.98) for the study data set and 0.87 (95% confidence interval, 0.81-0.94) in external validation. The negative predictive value to exclude pathology if a scan was classified as "normal" was 100% (25/25), and the positive predictive value was 97.6% (137/141). Sensitivity and specificity were 100% and 86%, respectively. In patients with inconclusive ratings, pathologies were found in 26 (63%) of 41 cases.

CONCLUSIONS: Our study provides the first clinical evaluation of a weakly supervised anomaly detection system for brain imaging. In an unselected, consecutive patient cohort, definite classification into normal/diseased was feasible in approximately two thirds of scans, going along with an excellent diagnostic accuracy and perfect negative predictive value for excluding pathology. Moreover, anomaly heat maps provide important guidance toward pathology interpretation, also in cases with inconclusive ratings.

来源:Invest Radiol,查看原文。版权归原作者所有。

引用

  1. Finck T, Schinz D, Grundl L, et al. Automated Pathology Detection and Patient Triage in Routinely Acquired Head Computed Tomography Scans. Invest Radiol. 2021. PMID: 33813571. doi:10.1097/RLI.0000000000000775

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。