文献速递神经MR

基于MRI影像组学的低级别胶质瘤1p/19q共缺失无创预测模型开发与外部验证

Development and external validation of a non-invasive molecular status predictor of chromosome 1p/19q co-deletion based on MRI radiomics analysis of Low Grade Glioma patients.
PubMed 文献 · Eur J Radiol · 2021-04-05

本研究回顾性分析209例病理确诊的低级别胶质瘤患者(训练集159例,验证集50例),从T2加权和T1加权增强MRI重采样数据中提取影像组学特征,采用随机森林分类器预测1p/19q共缺失状态。 Cubic和线性插值方法在外部验证集准确率均为0.72,临床效用指数分别为0.605和0.569,表明MRI影像组学具有预测1p/19q状态的潜力。

要点

  • MRI影像组学模型可在术前无创预测低级别胶质瘤1p/19q共缺失状态。
  • Cubic与线性插值方法在外部验证集准确率均为0.72,性能相似。
  • 模型临床效用指数负值(0.605/0.569)提示需进一步优化临床实用性。

核心结论

  • MRI影像组学具有预测低级别胶质瘤1p/19q共缺失状态的潜力。
  • Cubic和线性插值方法在外部验证中表现出相似性能,准确率均为0.72。

研究设计与样本

  • 回顾性研究,209例病理确诊的低级别胶质瘤患者来自癌症影像档案(TCIA)的2个数据集,训练集159例,验证集50例。
  • 从T2加权和T1加权增强MRI重采样数据中提取影像组学特征,采用线性和立方插值方法。
  • 每种重采样方法均采用三步特征选择法,在训练集上训练随机森林分类器,并在训练集和验证集上评估模型性能。

诊断标准与关键数值

  • 临床效用指数:立方插值0.605,线性插值0.569。

临床应用与阅片要点

  • 对于低级别胶质瘤,可探索使用T2加权和T1加权增强MRI影像组学特征无创预测1p/19q共缺失状态。
  • 立方与线性重采样方法性能相似,实际应用中可根据流程选择。

局限性

  • 回顾性研究,样本量有限(训练集159例,验证集50例),外部验证集较小。
  • 仅使用T2加权和T1加权增强MRI序列,未纳入其他序列或临床变量。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: The 1p/19q co-deletion status has been demonstrated to be a prognostic biomarker in lower grade glioma (LGG). The objective of this study was to build a magnetic resonance (MRI)-derived radiomics model to predict the 1p/19q co-deletion status.

METHOD: 209 pathology-confirmed LGG patients from 2 different datasets from The Cancer Imaging Archive were retrospectively reviewed; one dataset with 159 patients as the training and discovery dataset and the other one with 50 patients as validation dataset. Radiomics features were extracted from T2- and T1-weighted post-contrast MRI resampled data using linear and cubic interpolation methods. For each of the voxel resampling methods a three-step approach was used for feature selection and a random forest (RF) classifier was trained on the training dataset. Model performance was evaluated on training and validation datasets and clinical utility indexes (CUIs) were computed. The distributions and intercorrelation for selected features were analyzed.

RESULTS: Seven radiomics features were selected from the cubic interpolated features and five from the linear interpolated features on the training dataset. The RF classifier showed similar performance for cubic and linear interpolation methods in the training dataset with accuracies of 0.81 (0.75-0.86) and 0.76 (0.71-0.82) respectively; in the validation dataset the accuracy dropped to 0.72 (0.6-0.82) using cubic interpolation and 0.72 (0.6-0.84) using linear resampling. CUIs showed the model achieved satisfactory negative values (0.605 using cubic interpolation and 0.569 for linear interpolation).

CONCLUSIONS: MRI has the potential for predicting the 1p/19q status in LGGs. Both cubic and linear interpolation methods showed similar performance in external validation.