文献速递神经技术与安全MR

三维动脉自旋标记脑灌注成像中偶然显示的正常垂体腺可视化评估

Visualization of incidentally imaged pituitary gland on three-dimensional arterial spin labeling of the brain.
PubMed 文献 · Br J Radiol · 2021-04-29

该回顾性研究纳入93例垂体正常、因疑似脑疾病行三维伪连续动脉自旋标记(3D PCASL)脑灌注成像的患者,由两名观察者采用三级分级法评估垂体在CBF图上的可视化程度。结果显示观察者间一致性极好(加权κ=0.823),垂体体积中、大与Grade 3可视化显著相关,而年龄和性别无显著关联。结论认为正常垂体在3D PCASL上常表现为CBF高于皮质灰质,尤其在垂体体积较大者中。

要点

  • 正常垂体在3D PCASL CBF图上可表现为高灌注,易被误认为异常。
  • 垂体体积较大者更易出现CBF高于皮质灰质的Grade 3表现。
  • 观察者间分级一致性极好(加权κ=0.823),分级方法可重复。

核心结论

  • 正常垂体在3D PCASL上常显示CBF高于皮质灰质,尤其在垂体体积较大者中。
  • 垂体体积中、大与Grade 3可视化显著相关,年龄和性别无显著关联。

研究设计与样本

  • 回顾性纳入93例垂体正常、因疑似脑疾病行3D PCASL脑灌注成像的患者。
  • 由两名观察者独立采用三点分级系统评估垂体在CBF图上的可视化。
  • 采用加权κ统计量评价观察者间一致性,多因素logistic回归分析视觉分级与年龄、性别及垂体体积的关联。
  • 按垂体体积等分为小、中、大三组进行分组分析。

关键影像表现/征象

  • 垂体在PCASL CBF图上呈高灌注信号,分级依据垂体CBF与脑白质、皮质灰质CBF的比较。
  • Grade 1为垂体CBF≤脑白质CBF,Grade 2为脑白质CBF<垂体CBF≤皮质灰质CBF,Grade 3为皮质灰质CBF<垂体CBF。
  • 93例中Grade 1、2、3分别占17例(18.3%)、41例(44.1%)、35例(37.6%)。

诊断标准与关键数值

  • 可视化分级标准:Grade 1,垂体CBF≤脑白质CBF;Grade 2,脑白质CBF<垂体CBF≤皮质灰质CBF;Grade 3,皮质灰质CBF<垂体CBF。
  • 观察者间一致性加权κ=0.823。
  • 垂体体积中等与Grade 3可视化相关(p=0.0153,OR=4.8323,95%CI:1.3525–17.2649)。
  • 垂体体积大与Grade 3可视化相关(p=0.0009,OR=9.0299,95%CI:2.4663–33.0614)。

临床应用与阅片要点

  • 阅片时需注意正常垂体在3D PCASL CBF图上可呈高灌注,避免误判为病变。
  • 报告垂体区异常灌注时应结合垂体体积,体积较大者高灌注更可能为正常表现。
  • 采用三级分级法评估垂体可视化有助于提高观察者间一致性。

局限性

  • 回顾性研究设计。
  • 单中心研究。
  • 仅纳入垂体正常且因疑似脑疾病行3D PCASL的患者,可能存在选择偏倚。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To evaluate the visualization of incidentally imaged normal pituitary gland on three-dimensional (3D) pseudo continuous arterial spin labeling (PCASL) perfusion imaging of the brain.

METHODS: Ninety-three patients with a normal pituitary gland who underwent 3D PCASL for suspected brain diseases were retrospectively included. Visualization of the pituitary gland on PCASL cerebral blood flow (CBF) maps was assessed independently by two observers using a three-point grading system: Grade 1, pituitary CBF ≤ CBF of the cerebral white matter (WM); Grade 2, CBF of WM < pituitary CBF ≤ CBF of the cortical gray matter (GM); and Grade 3, CBF of GM < pituitary CBF. The interobserver agreement of visual grading was determined using weighted κ statistic. The associations of visual grades with age, sex, and pituitary volume were assessed using multivariate logistic regression. Pituitary glands were divided equally into three groups (small, medium, and large) according to their volume for categorization.

RESULTS: The interobserver agreement for visual rating was excellent (weighted κ = 0.823). Of the 93 cases, Grades 1, 2, and 3 included 17 (18.3%), 41 (44.1%), and 35 cases (37.6%), respectively. Medium and large pituitary volume were significantly associated with Grade 3 visualization (p = 0.0153, OR = 4.8323; 95% CI: 1.3525, 17.2649 and p = 0.0009; OR = 9.0299; 95% CI: 2.4663, 33.0614, respectively), whereas there was no significant association for age or sex.

CONCLUSION: The normal pituitary gland is often visualized with higher CBF than cortical GM on 3D PCASL, especially in individuals with larger pituitary volume.

ADVANCES IN KNOWLEDGE: Appearance of the normal pituitary gland on 3D PCASL has been documented for the first time.

来源:Br J Radiol,查看原文。版权归原作者所有。

引用

  1. Bohara M, Nakajo M, Kamimura K, et al. Visualization of incidentally imaged pituitary gland on three-dimensional arterial spin labeling of the brain. Br J Radiol. 2021. PMID: 33914621. doi:10.1259/bjr.20201311

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。