视神经鞘直径超声诊断颅内压升高的文献综述与Meta分析
该研究系统检索PUBMED和EMBASE,纳入18项前瞻性研究(其中16项含619例患者用于主要结局),比较超声测量视神经鞘直径(ONSD)与有创颅内压(ICP)监测的诊断准确性。结论认为ONSD是有用的辅助评估手段,但在有创方法可行时不能替代。
要点
- ONSD与有创ICP相关系数0.7(95%CI 0.63-0.76),仅作为辅助评估。
- 有创ICP监测可行时,ONSD不能替代有创方法。
核心结论
- ONSD超声是评估颅内压升高的有用辅助手段,但在有创ICP监测可行时不能替代有创方法。
研究设计与样本
- 系统综述与Meta分析,检索PUBMED和EMBASE,纳入18项前瞻性研究,其中16项研究含619例患者用于主要结局。
- 纳入成人疑似颅内压升高患者,比较超声ONSD测量与标准有创ICP测量,采用QUADAS-2工具评估研究质量。
- 采用双变量随机效应模型汇总敏感度、特异度和诊断比值比,通过Meta回归和亚组分析探讨异质性。
诊断标准与关键数值
- SROC曲线下面积0.93(95%CI 0.91-0.95,P<.05),ONSD与ICP相关系数0.7(95%CI 0.63-0.76,P<.05)。
- 仅1项研究为低质量,未见明显发表偏倚,异质性证据部分存在;Meta回归中无显著协变量。
- 严重创伤性脑损伤和脑实质ICP亚组分析未发现异质性。
临床应用与阅片要点
- ONSD超声可作为颅内压升高的辅助评估工具,尤其适用于有创ICP监测不可行或需快速筛查时。
- 报告时应结合临床背景,ONSD结果不能单独作为替代有创ICP监测的依据。
局限性
- 原文未明确报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
UNLABELLED: Optic nerve sheath diameter (ONSD) ultrasound is becoming increasingly more popular for estimating raised intracranial pressure (ICP). We performed a systematic review and analysis of the diagnostic accuracy of ONSD when compared to the standard invasive ICP measurement.
METHOD: We performed a systematic search of PUBMED and EMBASE for studies including adult patients with suspected elevated ICP and comparing sonographic ONSD measurement to a standard invasive method. Quality of studies was assessed using the QUADAS-2 tool by two independent authors. We used a bivariate model of random effects to summarize pooled sensitivity, specificity, and diagnostic odds ratio (DOR). Heterogeneity was investigated by meta-regression and sub-group analyses.
RESULTS: We included 18 prospective studies (16 studies including 619 patients for primary outcome). Only one study was of low quality, and there was no apparent publication bias. Pooled sensitivity was 0.9 [95% confidence intervals (CI): 0.85-0.94], specificity was 0.85 (95% CI: 0.8-0.89), and DOR was 46.7 (95% CI: 26.2-83.2) with partial evidence of heterogeneity. The Area-Under-the-Curve of the summary Receiver-Operator-Curve was 0.93 (95% CI: 0.91-0.95, P < .05). No covariates were significant in the meta-regression. Subgroup analysis of severe traumatic brain injury and parenchymal ICP found no heterogeneity. ICP and ONSD had a correlation coefficient of 0.7 (95% CI: 0.63-0.76, P < .05).
CONCLUSION: ONSD is a useful adjunct in ICP evaluation but is currently not a replacement for invasive methods where they are feasible.
引用
- Aletreby W, Alharthy A, Brindley PG, et al. Optic Nerve Sheath Diameter Ultrasound for Raised Intracranial Pressure: A Literature Review and Meta-analysis of its Diagnostic Accuracy. J Ultrasound Med. 2021. PMID: 33893746. doi:10.1002/jum.15732
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。