文献速递神经MR

脑转移瘤增强T2 FLAIR强化程度与DCE-MRI血管通透性参数的相关性分析

Enhancement degree of brain metastases: correlation analysis between enhanced T2 FLAIR and vascular permeability parameters of dynamic contrast-enhanced MRI.
PubMed 文献 · Eur Radiol · 2021-04-13

结果显示CE-T2 FLAIR强化程度与Ktrans、Kep呈负相关,组A的Ktrans和Kep显著低于组C,Ve组间无差异。提示血管通透性参数可解释CE-T2 FLAIR与CE-BRAVO强化差异,CE-T2 FLAIR有助于检出血脑屏障轻度破坏的脑转移瘤。

要点

  • CE-T2 FLAIR强化程度与Ktrans、Kep负相关,强化越高通透性越低。
  • CE-T2 FLAIR对血脑屏障轻度破坏的脑转移瘤检出有帮助。
  • Ve在各强化程度组间无显著差异,不解释强化差异。

关键影像表现/征象

  • CE-T2 FLAIR强化程度按与CE-BRAVO比较分为高于(A组31个)、相等(B组19个)、低于(C组32个)。
  • Ktrans和Kep与CE-T2 FLAIR的CR呈负相关(ρ=-0.551,p<0.001;ρ=-0.708,p<0.001)。
  • Ktrans和Kep与CE-T2 FLAIR的PI呈负相关(ρ=-0.511,p<0.001;ρ=-0.621,p<0.001)。
  • A组Ktrans和Kep显著低于C组(均p<0.001)。
  • Ve在各组间无显著差异(p=0.327)。

诊断标准与关键数值

  • CE-T2 FLAIR强化程度视觉分级:与CE-BRAVO比较,高于为A组、相等为B组、低于为C组。
  • Ktrans和Kep与CR的相关系数分别为ρ=-0.551(p<0.001)和ρ=-0.708(p<0.001)。
  • Ktrans和Kep与PI的相关系数分别为ρ=-0.511(p<0.001)和ρ=-0.621(p<0.001)。
  • A组与C组Ktrans和Kep比较均p<0.001;Ve组间比较p=0.327。

临床应用与阅片要点

  • 阅读CE-T2 FLAIR时,强化程度高于CE-BRAVO的病灶可能对应较低Ktrans和Kep,提示血脑屏障破坏较轻。
  • CE-T2 FLAIR可用于辅助检出血脑屏障轻度破坏的脑转移瘤,减少漏诊。
  • Ve不解释CE-T2 FLAIR与CE-BRAVO的强化差异,报告时不必过度依赖Ve。

局限性

  • 原文未报告敏感度、特异度、AUC等诊断效能指标。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To investigate the correlation between enhancement degrees of brain metastases on contrast-enhanced T2-fluid-attenuated inversion recovery (CE-T2 FLAIR) and vascular permeability parameters of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI).

METHODS: Thirty-nine patients with brain metastases were prospectively collected. They underwent non-enhanced T2 FLAIR, DCE-MRI, CE-T2 FLAIR, and contrast-enhanced three-dimensional brain volume imaging (CE-BRAVO). Quantitative parameters of DCE-MRI were evaluated for all lesions, which included volume transfer constant (Ktrans), rate constant (Kep), and fractional volume of the extracellular extravascular space (Ve). Contrast ratio (CR) and percentage increase (PI) values of all lesions on CE-T2 FLAIR were also measured. The tumor enhancement degree on CE-T2 FLAIR in relation to CE-BRAVO was visually classified as higher (group A), equal (group B), and lower (group C).

RESULTS: A total of 82 brain metastases were evaluated, including 31 in group A, 19 in group B, and 32 in group C. The Ktrans and Kep were negatively correlated with the CR (ρ = - 0.551, p < 0.001 and ρ = - 0.708, p < 0.001, respectively) and PI (ρ = - 0.511, p < 0.001 and ρ = - 0.621, p < 0.001, respectively). The Ktrans and Kep of group A were significantly lower than those of group C (both p < 0.001). No significant difference was found in Ve among the groups (p = 0.327).

CONCLUSIONS: The enhancement degree of brain metastases on CE-T2 FLAIR is negatively correlated with Ktrans and Kep values, which indicate that vascular permeability parameters may play an important role in explaining the difference in enhancement between CE-T2 FLAIR and CE-BRAVO.

KEY POINTS: • The enhancement degree on CE-T2 FLAIR was negatively correlated with Ktrans and Kep values. • The vascular permeability of brain metastasis accounted for the difference in enhancement degree between CE-T2 FLAIR and CE-BRAVO. • CE-T2 FLAIR is useful for detecting brain metastases with mild disruption of the blood-brain barrier.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Jin T, Zhang H, Liu X, et al. Enhancement degree of brain metastases: correlation analysis between enhanced T2 FLAIR and vascular permeability parameters of dynamic contrast-enhanced MRI. Eur Radiol. 2021. PMID: 33847812. doi:10.1007/s00330-020-07625-8

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。