短脉冲相位键控聚焦超声开放大鼠血脊髓屏障的参数研究

Focused Ultrasound-Induced Blood-Spinal Cord Barrier Opening Using Short-Burst Phase-Keying Exposures in Rats: A Parameter Study.
PubMed 文献 · Ultrasound Med Biol · 2021-04-18

本研究在大鼠中探究短脉冲相位键控聚焦超声开放血脊髓屏障的参数效应,发现原位声压从0.23增至0.33 MPa可显著增加MRI T1加权对比增强(p=0.015),爆发长度从2周期增至5周期(514 kHz)亦显著增加增强(p=0.014)。治疗时长120 vs 300 s和爆发重复频率20 vs 40 kHz的增强差异未达统计学显著(分别为p=0.056和p=0.064),但后者与组织学损伤增加相关。脉冲长度2 ms与10 ms间增强无差异(p=0.912)。

要点

  • 增高原位声压(0.23–0.33 MPa)或增长爆发长度(2→5周期,514 kHz)可显著增强血脊髓屏障开放程度。
  • 爆发重复频率增至40 kHz虽未显著增加增强,但组织学损伤增加,需权衡安全性。
  • 脉冲长度2 ms与10 ms增强效果无差异,短脉冲或允许更多靶点穿插以扩大治疗体积。

关键影像表现/征象

  • 原位声压从0.23增至0.33 MPa导致治疗后MRI T1加权对比增强增加(p=0.015)。
  • 爆发长度从2周期增至5周期(514 kHz)导致增强增加(p=0.014)。
  • 爆发重复频率从20增至40 kHz对应组织学损伤增加。
  • 脉冲长度2 ms与10 ms间增强无差异(p=0.912),记录的第二谐波信号在脉冲前2 ms内急剧下降。

诊断标准与关键数值

  • 原位声压0.23–0.33 MPa范围与T1加权对比增强正相关(p=0.015)。
  • 爆发长度2 vs 5周期(514 kHz)与增强正相关(p=0.014)。
  • 治疗时长120 vs 300 s的增强差异未达统计学显著(p=0.056)。
  • 爆发重复频率20 vs 40 kHz的增强差异未达统计学显著(p=0.064)。
  • 脉冲长度2 vs 10 ms的增强无差异(p=0.912)。

临床应用与阅片要点

  • 阅片时关注脊髓T1加权增强程度以评估血脊髓屏障开放效果。
  • 需注意高爆发重复频率(40 kHz)可能伴随组织学损伤,阅片时应警惕相应损伤征象。
  • 短脉冲长度(2 ms)在保持增强效果的同时可能允许更多靶点治疗。

局限性

  • 研究为大鼠临床前实验,结果向人体转化需进一步验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Transient opening of the blood-spinal cord barrier has the potential to improve drug delivery options to the spinal cord. We previously developed short-burst phase-keying exposures to reduce focal depth of field and mitigate standing waves in the spinal canal. However, optimal short-burst phase-keying parameters for drug delivery have not been identified. Here, the effects of pressure, treatment duration, pulse length, burst repetition frequency and burst length on resulting tissue effects were investigated. Increased in situ pressures (0.23-0.33 MPa) led to increased post-treatment T1-weighted contrast enhancement in magnetic resonance imaging (p = 0.015). Increased treatment duration (120 vs. 300 s) led to increased enhancement, but without statistical significance (p = 0.056). Increased burst repetition frequency (20 vs. 40 kHz) yielded a non-significant increase in enhancement (p = 0.064) but corresponded with increased damage observed on histology. No difference was observed in enhancement between pulse lengths of 2 and 10 ms (p = 0.912), corresponding with a sharp drop in the recorded second harmonic signal during the first 2 ms of the pulse. Increasing the burst length from two to five cycles (514 kHz) led to increased enhancement (p = 0.014). Results indicate that increasing the burst length may be the most effective method to enhance drug delivery. Additionally, shorter pulse lengths may allow more interleaved targets, and therefore a larger treatment volume, within one sonication.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Fletcher SP, Choi M, Ramesh R, et al. Focused Ultrasound-Induced Blood-Spinal Cord Barrier Opening Using Short-Burst Phase-Keying Exposures in Rats: A Parameter Study. Ultrasound Med Biol. 2021. PMID: 33879388. doi:10.1016/j.ultrasmedbio.2021.03.007

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。