磁共振波谱在内侧颞叶硬化中的应用:系统综述
该系统综述检索了PubMed、SCOPUS和Cochrane数据库,最终纳入30篇关于磁共振波谱(MRS)在内侧颞叶硬化(MTS)中应用的文章。主要发现为同侧海马N-乙酰天冬氨酸(NAA)降低,且海马外区域NAA也降低,提示MTS可能是更广泛的疾病。MRS有助于术前定位致痫灶,但对MTS诊断不具特异性。
要点
- MTS患者同侧海马NAA降低,NAA/Cho+Cr和NAA/Cr比值下降。
- 海马外区域NAA水平也降低,提示MTS可能为更广泛的疾病。
- 无MTS患者同侧海马NAA也降低,但MTS患者更低,MRS对MTS诊断不特异。
核心结论
- MRS主要发现为同侧海马NAA降低,海马外区域NAA也降低,提示MTS可能是更广泛的疾病。
- 无MTS患者同侧海马NAA也降低,但MTS患者更低,MRS对MTS诊断不特异。
- MRS可用于术前评估定位致痫灶,但并非MTS的特异性诊断工具。
研究设计与样本
- 系统综述,检索PubMed、SCOPUS和Cochrane数据库,使用MESH词包括磁共振波谱、质子磁共振波谱、碳-13磁共振波谱、1H-MRS、31P-MRS、内侧颞叶硬化、海马硬化、内侧颞叶癫痫等。
- 初始检索到134篇文章,经排除流程后最终纳入30篇。
关键影像表现/征象
- 13项研究检测到同侧海马N-乙酰天冬氨酸(NAA)降低。
- 9项研究显示同侧海马NAA/Cho+Cr比值降低。
- 8项研究显示同侧海马NAA/Cr比值降低。
- 9项研究还发现海马外区域NAA水平降低。
临床应用与阅片要点
- MRS可用于术前评估以定位致痫灶,但不应仅凭MRS诊断MTS。
- 注意无MTS患者也可能出现同侧海马NAA降低,需结合其他影像和临床信息。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND: Magnetic resonance spectroscopy (MRS) provides non-invasive information about metabolic features in different regions of the brain affected by mesial temporal sclerosis (MTS).
PURPOSE: To review articles analyzing the most common alterations in biochemical parameters in MTS and the applications of MRS in presurgical assessment.
METHODS: We undertook a systematic literature search for MRS in MTS in PubMed, SCOPUS, and Cochrane based on the MESH terms ""Magnetic Resonance Spectroscopy", "Proton Magnetic Resonance Spectroscopy", "Carbon-13 Magnetic Resonance Spectroscopy", "1H-MRS", "31P-MRS", "mesial temporal sclerosis", "hippocampal sclerosis", "mesial temporal seizure", and "mesial temporal epilepsy".
RESULTS: Of the initial 134 articles found, 30 were selected after the exclusion process. Of these, 13 detected a decrease in N-acetylaspartate (NAA), 9 showed a decreased in the ratio NAA/Cho+Cr, and 8 demonstrated a decreased in the ratio NAA/Cr, all of them in the ipsilateral hippocampus. Nine studies also found reduced NAA levels in extrahippocampal regions.
CONCLUSIONS: The main findings were a decrease in NAA in the ipsilateral hippocampus. In addition, NAA levels were low outside the hippocampus so MTS could be a more extensive disease. Patients without MTS also presented a decrease in NAA in the ipsilateral hippocampus although NAA was even lower in the MTS patients. Thus, MRS could be useful in the presurgical evaluation to locate the epileptogenic focus, but not specific for the diagnosis of MTS.
引用
- Fernández-Vega N, Ramos-Rodriguez JR, Alfaro F, et al. Usefulness of magnetic resonance spectroscopy in mesial temporal sclerosis: a systematic review. Neuroradiology. 2021. PMID: 33851253. doi:10.1007/s00234-021-02704-z
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。