RSNA-STR-ACR COVID-19 CT分型共识:240例连续患者的阅片者间一致性及与RT-PCR状态关联
该回顾性研究纳入240例同时行胸部CT和RT-PCR的连续患者,由2名胸部放射科医师独立按RSNA-STR-ACR共识分型判读。RT-PCR阳性组最常见为典型型(75.9%),阅片者间一致性加权κ为0.90(95%CI 0.80-0.96),CT严重度评分读者间平均差异-0.07(95%CI -0.48至0.34),视觉评估无显著差异。
要点
- 典型型CT表现与RT-PCR阳性高度相关,阅片者间一致性高(κ=0.90)。
- RT-PCR阳性组最常见征象为磨玻璃影(80.5%)、铺路石征(32.2%)、圆形假结节状磨玻璃影(22.9%)。
- CT严重度评分视觉评估读者间无显著差异,可重复性好。
关键影像表现/征象
- RT-PCR阳性组最常见CT征象为磨玻璃影(80.5%)、铺路石征(32.2%)、圆形假结节状磨玻璃影(22.9%)。
- RT-PCR阳性组CT分型以典型型最常见(75.9%),其次为阴性型(17.1%)。
诊断标准与关键数值
- RT-PCR阳性组CT分型典型型占75.9%,阴性型占17.1%。
- 阅片者间一致性加权κ为0.90(95%CI 0.80-0.96)。
- CT严重度评分读者间平均差异为-0.07(95%CI -0.48至0.34),视觉评估无显著差异。
临床应用与阅片要点
- 日常阅片可按RSNA-STR-ACR共识对COVID-19 CT表现分型,典型型提示RT-PCR阳性可能性高。
- 关注磨玻璃影、铺路石征和圆形假结节状磨玻璃影等典型征象,有助于提高报告一致性。
- CT严重度评分视觉评估可重复性好,可用于半定量评估。
局限性
- 回顾性单中心研究,样本量240例,结论外推需谨慎。
- 仅由2名胸部放射科医师判读,未评估不同经验水平医师间的一致性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: The aim of this study was to study interreader agreement of the RSNA-STR-ACR (Radiological Society of North America/Society of Thoracic Radiology/American College of Radiology) consensus statement on reporting chest computed tomography (CT) findings related to COVID-19 on a sample of consecutive patients confirmed with reverse transcriptase-polymerase chain reaction (RT-PCR) for severe acute respiratory syndrome coronavirus 2.
MATERIALS AND METHODS: This institutional review board-approved retrospective study included 240 cases with a mean age of 47.6 ± 15.9 years, ranging from 20 to 90 years, who had a chest CT and RT-PCR performed. Computed tomography images were independently analyzed by 2 thoracic radiologists to identify patterns defined by the RSNA-STR-ACR consensus statement, and concordance was determined with weighted κ tests. Also, CT findings and CT severity scores were tabulated and compared.
RESULTS: Of the 240 cases, 118 had findings on CT. The most frequent on the RT-PCR-positive group were areas of ground-glass opacities (80.5%), crazy-paving pattern (32.2%), and rounded pseudonodular ground-glass opacities (22.9%). Regarding the CT patterns, the most frequent in the RT-PCR-positive group was typical in 75.9%, followed by negative in 17.1%. The interreader agreement was 0.90 (95% confidence interval, 0.80-0.96) in this group. The CT severity score had a mean difference of -0.07 (95% confidence interval, -0.48 to 0.34) among the readers, showing no significant differences regarding visual estimation.
CONCLUSIONS: The RSNA-STR-ACR consensus statement on reporting chest CT patterns for COVID-19 presents a high interreader agreement, with the typical pattern being more frequently associated with RT-PCR-positive examinations.
引用
- Silva CF, Alegria J, Ramos C, et al. RSNA-STR-ACR Consensus Statement for COVID-19 CT Patterns: Interreader Agreement in 240 Consecutive Patients and Association With RT-PCR Status. J Comput Assist Tomogr. 2021. PMID: 33797444. doi:10.1097/RCT.0000000000001162
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。