文献速递胸部CT

循环生成对抗网络在超低剂量CT评估肺结核中的辐射剂量降低与图像质量改善作用

Cycle-Consistent Generative Adversarial Network: Effect on Radiation Dose Reduction and Image Quality Improvement in Ultralow-Dose CT for Evaluation of Pulmonary Tuberculosis.
PubMed 文献 · Korean J Radiol · 2021-03-09

该前瞻性研究纳入103例肺结核患者,先行标准剂量CT(120 kVp自动曝光控制),随即行超低剂量CT(80 kVp、10 mAs),利用CycleGAN进行图像去噪并与混合迭代重建及基于模型的迭代重建比较。结果显示CycleGAN去噪图像噪声(19.5±3.0 HU)显著低于混合迭代重建(66.3±10.5 HU,p<0.001),与基于模型的迭代重建(19.6±2.6 HU,p>0.908)相似,且病灶对比噪声比最高;超低剂量CT平均有效辐射剂量0.12 mSv,较标准剂量CT降低93.9%。结论认为优化CycleGAN技术可从超低剂量胸部CT合成诊断可接受的图像用于肺结核评估。

要点

  • 超低剂量CT(80 kVp、10 mAs)平均有效剂量仅0.12 mSv,较标准剂量CT降低93.9%。
  • CycleGAN去噪后图像噪声与基于模型的迭代重建相当,病灶对比噪声比最高。
  • CycleGAN生成的超低剂量CT图像对解剖结构和病理征象的显示满足诊断需求。

核心结论

  • 优化CycleGAN技术可从超低剂量胸部CT合成诊断可接受的图像,用于肺结核评估。

研究设计与样本

  • 所有患者先接受标准剂量CT(120 kVp,自动曝光控制),随即接受超低剂量CT(80 kVp、10 mAs)。
  • 两次连续扫描图像用于训练CycleGAN框架进行图像到图像转换,并与混合迭代重建及基于模型的迭代重建比较去噪效果。
  • 客观测量采用重复测量方差分析,主观图像质量评分采用Wilcoxon符号秩检验比较。

关键影像表现/征象

  • CycleGAN生成的去噪超低剂量CT图像对解剖结构和病理征象的显示达到满意图像质量。
  • CycleGAN图像噪声(均值±标准差19.5±3.0 HU)显著低于混合迭代重建(66.3±10.5 HU,p<0.001),与基于模型的迭代重建(19.6±2.6 HU,p>0.908)相似。
  • CycleGAN生成图像的肺部病灶对比噪声比最高,其次为基于模型的迭代重建和混合迭代重建。

诊断标准与关键数值

  • 以超低剂量CT图像为输入,优化CycleGAN去噪模型的峰值信噪比提升2.0 dB,结构相似性指数提升0.21。
  • 超低剂量CT平均有效辐射剂量为0.12 mSv,较标准剂量CT平均降低93.9%。

临床应用与阅片要点

  • 在超低剂量胸部CT(80 kVp、10 mAs)肺结核评估中,可采用CycleGAN去噪替代或补充迭代重建以进一步降低辐射剂量。
  • 阅片时注意CycleGAN去噪图像噪声水平与基于模型的迭代重建相当,病灶对比噪声比最高,但需结合原始超低剂量图像排除伪影或过度平滑。

局限性

  • 单中心前瞻性研究,样本量103例,需外部验证。
  • CycleGAN模型基于同一组患者的连续两次扫描训练,可能存在数据泄漏风险。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To investigate the image quality of ultralow-dose CT (ULDCT) of the chest reconstructed using a cycle-consistent generative adversarial network (CycleGAN)-based deep learning method in the evaluation of pulmonary tuberculosis.

MATERIALS AND METHODS: Between June 2019 and November 2019, 103 patients (mean age, 40.8 ± 13.6 years; 61 men and 42 women) with pulmonary tuberculosis were prospectively enrolled to undergo standard-dose CT (120 kVp with automated exposure control), followed immediately by ULDCT (80 kVp and 10 mAs). The images of the two successive scans were used to train the CycleGAN framework for image-to-image translation. The denoising efficacy of the CycleGAN algorithm was compared with that of hybrid and model-based iterative reconstruction. Repeated-measures analysis of variance and Wilcoxon signed-rank test were performed to compare the objective measurements and the subjective image quality scores, respectively.

RESULTS: With the optimized CycleGAN denoising model, using the ULDCT images as input, the peak signal-to-noise ratio and structural similarity index improved by 2.0 dB and 0.21, respectively. The CycleGAN-generated denoised ULDCT images typically provided satisfactory image quality for optimal visibility of anatomic structures and pathological findings, with a lower level of image noise (mean ± standard deviation [SD], 19.5 ± 3.0 Hounsfield unit [HU]) than that of the hybrid (66.3 ± 10.5 HU, p < 0.001) and a similar noise level to model-based iterative reconstruction (19.6 ± 2.6 HU, p > 0.908). The CycleGAN-generated images showed the highest contrast-to-noise ratios for the pulmonary lesions, followed by the model-based and hybrid iterative reconstruction. The mean effective radiation dose of ULDCT was 0.12 mSv with a mean 93.9% reduction compared to standard-dose CT.

CONCLUSION: The optimized CycleGAN technique may allow the synthesis of diagnostically acceptable images from ULDCT of the chest for the evaluation of pulmonary tuberculosis.

来源:Korean J Radiol,查看原文。版权归原作者所有。

引用

  1. Yan C, Lin J, Li H, et al. Cycle-Consistent Generative Adversarial Network: Effect on Radiation Dose Reduction and Image Quality Improvement in Ultralow-Dose CT for Evaluation of Pulmonary Tuberculosis. Korean J Radiol. 2021. PMID: 33739634. doi:10.3348/kjr.2020.0988

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。