该研究回顾性收集3家医院153例直径小于5cm的肝细胞癌患者TACE术前MRI及临床资料,构建基于T2WI和DCE-MR动脉期的影像组学模型、临床模型及列线图,用于预测TACE短期疗效。结果显示列线图预测效能优于单一影像组学或临床模型,且基于T2WI与基于DCE-MRI动脉期的模型效能几乎相等。

要点

  • 列线图预测TACE短期疗效的AUC在训练集和验证集分别为0.83和0.81
  • 基于T2WI与基于DCE-MRI动脉期的模型预测效能几乎相等
  • 列线图预测效能优于单独影像组学模型或临床模型

核心结论

  • 基于MRI的列线图预测TACE短期疗效的效能优于单独影像组学模型或临床模型。
  • 基于T2WI的模型与基于DCE-MRI动脉期的模型预测效能几乎相等。

研究设计与样本

  • 回顾性收集3家医院153例直径小于5cm的肝细胞癌患者TACE术前MRI图像及临床数据。
  • 医院1的113例为训练集,其他医院的40例为外部验证集。
  • 分别基于T2WI和DCE-MR动脉期图像构建影像组学模型、临床模型及列线图。
  • 采用多因素logistic回归建模,以ROC曲线评估各模型预测性能。

诊断标准与关键数值

  • 最终筛选出11个T2WI特征和11个DCE-MRI动脉期特征用于建模。
  • 基于T2WI的列线图在训练集和验证集的AUC分别为0.83和0.81。

临床应用与阅片要点

  • 阅片时可关注T2WI和DCE-MRI动脉期图像提取的影像组学特征,辅助预测TACE短期疗效。
  • 列线图可作为术前无创评估工具,帮助识别可能从TACE获益的直径小于5cm肝细胞癌患者。

局限性

  • 回顾性研究设计。
  • 验证集样本量较小(40例)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To construct MRI radiomics nomograms that can predict short-term response after TACE in HCC patients with diameter less than 5 cm.

METHODS: MRI images and clinical data of 153 cases with tumor diameter less than 5 cm before TACE from 3 hospitals were collected retrospectively and divided into 1 internal training set and 1 external validation set. The T2-weighted imaging (T2WI) and dynamic contrast-enhanced MRI arterial phase (DCE-MR AP) images were studied. Multivariable logistic regression was used to construct Radiomics models, Clinics models, and Nomograms based on T2WI and DCE-MR AP, respectively. The receiver characteristic curve (ROC) was used to evaluate the predictive performance of each model.

RESULTS: In this study, 113 eligible cases in Hospital 1 were collected as the training set, and 40 eligible cases in other hospitals were used as the verification set. 11 T2WI features and 11 DCE-MRI AP features with the most predictive value were finally screened. 3 models based on T2WI and 3 models based on DCE-MRI AP were established, respectively. The area under curve (AUC) value of Nomogram based on T2WI of training set and validation set was 0.83 and 0.81, respectively. The AUC value of the models based on T2WI and models based on AP was almost equal, and Nomograms were the most effective models among all three types of models.

CONCLUSION: MRI-based Nomogram has greater predictive efficacy to predict the response after TACE than Radiomics and Clinics models alone, and the efficacy of T2WI-based models and DCE-MRI AP-based models was almost equal.