文献速递神经介入外周血管DSA

压力锅技术血管内治疗脊髓动静脉瘘:15例经验

Pressure Cooker Technique for Endovascular Treatment of Spinal Arteriovenous Fistulas: Experience in 15 Cases.
PubMed 文献 · AJNR Am J Neuroradiol · 2021-03-25

本文报道了2家机构采用压力锅技术对15例脊髓动静脉瘘(12例硬脊膜瘘、3例硬脊膜外瘘)进行血管内栓塞的初步经验。技术成功实现近端封堵,随访完全闭塞率91.7%,临床改善率71%,仅1例短暂性神经根缺血并发症。结果表明该技术安全有效,但需注意延迟复发风险。

要点

  • 压力锅技术可用于脊髓动静脉瘘栓塞,近端封堵联合稀释胶或EVOH。
  • 随访完全闭塞率91.7%,但需警惕延迟复发(8.3%)。
  • 主要并发症为短暂性神经根缺血,发生率6.7%。

诊断标准与关键数值

  • 完全闭塞定义为随访血管造影显示脊髓动静脉瘘无显影,随访12例中11例(91.7%)达到。
  • 临床改善定义为随访时临床症状改善,随访14例中10例(71%)达到。
  • 1例(8.3%)在29个月时出现延迟复发。

临床应用与阅片要点

  • 压力锅技术可作为脊髓动静脉瘘的血管内治疗选择,尤其适用于需要近端封堵的病例。
  • 术后需长期血管造影随访,警惕延迟复发,即使初期完全闭塞。
  • 注意神经根缺血风险,操作时需谨慎避免栓塞剂反流至神经根供血动脉。

局限性

  • 样本量小(15例),为初步经验。
  • 回顾性设计,缺乏对照组。
  • 随访时间不完全统一,部分患者缺乏临床或血管造影随访。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: Spinal arteriovenous fistulas are challenging to cure by endovascular means, with a risk of incomplete occlusion or delayed recurrence. The authors report herein their preliminary experience using the pressure cooker technique for the embolization of spinal arteriovenous fistulas.

MATERIALS AND METHODS: Fifteen patients (8 men; mean age, 60.3 years) underwent an endovascular treatment of a spinal arteriovenous fistula (12 dural spinal arteriovenous fistulas and 3 epidural spinal arteriovenous fistulas) in 2 different institutions using the pressure cooker technique. Two microcatheters could be navigated in the segmental artery in all patients using 2 guiding catheters. A proximal plug was achieved with highly concentrated cyanoacrylate ± coils. The liquid embolic agent injected to cure the fistula was diluted cyanoacrylate (n = 11) or ethylene-vinyl alcohol (n = 4). Technical and clinical complications were systematically recorded. Clinical and angiographic outcomes were systematically evaluated at follow-up.

RESULTS: One (6.7%) procedure-related complication was recorded, which consisted of a transient radicular deficit, related to nerve root ischemia. Clinical improvement was observed in 10/14 (71%) patients for whom clinical follow-up was available. Complete spinal arteriovenous fistula occlusion on a follow-up angiography was observed in 11/12 patients (91.7%) for whom angiographic follow-up was available. One patient (8.3%) presented with a delayed recurrence at 29 months.

CONCLUSIONS: The pressure cooker technique is feasible, with either glue or ethylene-vinyl alcohol, for the embolization of spinal arteriovenous fistulas. Our results suggest the safety and effectiveness of this technique.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Clarençon F, Stracke CP, Shotar E, et al. Pressure Cooker Technique for Endovascular Treatment of Spinal Arteriovenous Fistulas: Experience in 15 Cases. AJNR Am J Neuroradiol. 2021. PMID: 33766821. doi:10.3174/ajnr.A7078

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。