介入技术取出Y型气道自膨式覆膜金属支架
该回顾性研究分析了33例患者35枚Y型气道自膨式覆膜金属支架的取出经验,平均留置101.7±105.4天。4例采用常规法(抓取支架上端使其塌陷并收拢近端),31例采用翻转法(抓取远端使支架内翻后剥离取出),取出操作时间24.3±12.4分钟(中位20分钟)。结论认为介入放射学技术取出Y型气道支架可行、安全、有效,可考虑临床应用。
要点
- Y型气道覆膜金属支架可在透视下经介入技术安全取出,翻转法适用于多数病例。
- 常规法抓取支架上端塌陷收拢,翻转法抓取远端内翻剥离,操作时间约20-24分钟。
- 平均支架留置时间约101.7天,取出前需评估支架位置及与气道壁关系。
核心结论
- 介入放射学技术是取出Y型气道自膨式覆膜金属支架可行、安全、有效的方法,可考虑在临床中应用。
研究设计与样本
- 回顾性分析2011年3月至2019年8月33例取出Y型气道自膨式覆膜金属支架患者的临床资料,共取出35枚支架,在透视下经介入技术完成。
诊断标准与关键数值
- 常规法为抓取支架上端使其塌陷并收拢近端,共4例;翻转法为抓取支架远端使其内翻后剥离取出,共31例。
- 气管支架平均留置时间为101.7±105.4天;取出操作时间为24.3±12.4分钟(中位时间20分钟)。
临床应用与阅片要点
- 阅片或操作前应明确支架类型、位置及留置时间,根据支架形态选择常规法或翻转法取出。
- 翻转法通过抓取远端内翻剥离,可能适用于常规法难以塌陷收拢的Y型支架。
局限性
- 本研究为单中心回顾性分析,样本量33例,未设对照组,结论需更大样本前瞻性研究验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIM: To review the removal of Y-shaped airway self-expanding covered metallic stents using the interventional technique under fluoroscopy.
MATERIALS AND METHODS: The clinical data of 33 patients who underwent removal of Y-shaped airway self-expanding covered metallic stents from March 2011 to August 2019 were analysed retrospectively.
RESULTS: A total of 35 Y-shaped stents were removed. The average indwelling duration of the tracheal stents was 101.7 ± 105.4 days. Four cases were removed via the conventional method (grasping the upper tip of the stent to collapse and adduct the proximal end of the stent), whereas 31 cases were removed using the reversal method (grasping the distal end of the stent to invert and strip out the stent). The duration of stent removal was 24.3 ± 12.4 minutes (median time, 20 minutes).
CONCLUSION: The interventional radiology technique is a feasible, safe, and effective method for removing Y-shaped airway self-expanding covered metallic stents, and can be considered for use in the clinical setting.
引用
- Zhao Y, Zeng YW, Yin MP, et al. Y-shaped airway self-expanding covered metallic stent removal via the interventional technique. Clin Radiol. 2021. PMID: 33691949. doi:10.1016/j.crad.2021.02.002
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。