文献速递骨肌儿科影像技术与安全US

床旁超声旋前方肌血肿征检测儿童临床无成角前臂远端骨折

Point-of-Care Ultrasound Pronator Quadratus Hematoma Sign for Detection of Clinically Non-Angulated Pediatric Distal Forearm Fractures: A Prospective Cohort Study.
PubMed 文献 · J Ultrasound Med · 2021-03-10

所有22例皮质断裂骨折均出现PQH征,16例无皮质断裂骨折均无PQH征,诊断准确率100%。

要点

  • PQH征阳性提示儿童前臂远端皮质断裂骨折,阴性可排除。
  • 皮质断裂骨折PQ delta厚度均≥2.1mm,无骨折或隆突骨折均≤1.1mm。
  • 超声可作为临床无成角损伤的辅助诊断工具,但需更大样本验证。

关键影像表现/征象

  • PQH征表现为旋前方肌区域血肿形成,在皮质断裂骨折患儿中均出现。
  • 皮质断裂骨折组PQ delta厚度范围为2.1至10.2mm。
  • 隆突骨折组PQ delta厚度范围为0.0至1.1mm。
  • 无骨折组PQ delta厚度范围为0.2至0.8mm。

诊断标准与关键数值

  • PQH征诊断皮质断裂骨折的敏感度100%(95%CI: 85-100%),特异度100%(95%CI: 79-100%)。
  • PQ delta厚度≥2.1mm提示皮质断裂骨折,≤1.1mm提示无皮质断裂骨折。

临床应用与阅片要点

  • 对临床无成角的儿童前臂远端损伤,可尝试床旁超声观察PQH征辅助诊断。
  • 测量双侧旋前方肌厚度差(PQ delta)可作为补充指标,注意阈值2.1mm和1.1mm。
  • 超声结果需结合X线,避免仅凭超声决定治疗。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: Point-of-care ultrasound (POCUS) diagnosis of distal forearm fractures relies on the identification of buckling or breach of hyperechoic bone cortex. We describe the pronator quadratus hematoma (PQH) formation visualized on POCUS, the PQH sign, as it may aid diagnosis of pediatric distal forearm cortical breach fractures.

METHODS: A prospective cohort of children presenting to an emergency department with isolated, clinically non-angulated distal forearm injuries received POCUS by an expert emergency physician sonologist who identified the presence or absence of the PQH sign. They secondarily recorded the difference between the size of the pronator quadratus (PQ) muscle on both the affected and non-affected forearms (PQ delta thickness). Children received an x-ray subsequent to POCUS and were diagnosed based on an x-ray reported by a radiologist masked to POCUS findings.

RESULTS: Thirty-eight children were recruited. All 22 patients with cortical breach fracture had PQH sign present (100%; 95%CI: 85-100%), while all 16 patients without cortical breach fracture had PQH sign absent (100%; 95%CI: 79-100%). PQ delta thickness ranged from 2.1 to 10.2 mm in cortical breach fractures, 0.0 to 1.1 mm in buckle fractures, and 0.2 to 0.8 mm in patients without fracture.

CONCLUSIONS: The PQH sign correctly distinguished all children with, and without, cortical breach fractures. All PQ delta thicknesses were ≧2.1 mm when cortical breach fracture was present and ≦1.1 mm when cortical breach fracture was absent. The PQH sign and PQ delta thickness are promising measurements to identify pediatric distal forearm cortical breach fractures, and their utility should be confirmed in larger studies with sonologists of different abilities.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Snelling PJ, Keijzers G, Ware RS, et al. Point-of-Care Ultrasound Pronator Quadratus Hematoma Sign for Detection of Clinically Non-Angulated Pediatric Distal Forearm Fractures: A Prospective Cohort Study. J Ultrasound Med. 2021. PMID: 33749859. doi:10.1002/jum.15695

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。