低光子能量图像联合ASIR在肾脏双能CT血管成像中降低对比剂剂量

Reducing contrast medium dose with low photon energy images in renal dual-energy spectral CT angiography and adaptive statistical iterative reconstruction (ASIR).
PubMed 文献 · Br J Radiol · 2021-03-12

一项随机对照研究将40例肾脏CTA患者分为600 mgI/kg组(70 keV图像)和300 mgI/kg组(40-70 keV单能图像),均采用40%ASIR重建。结果显示300 mgI/kg组对比剂剂量减半,其40 keV图像的ΔCT和CNR与常规组相当,SNR更高,主观评分良好。结论认为低能量图像联合ASIR可在维持图像质量的同时将对比剂剂量降低50%。

要点

  • 肾脏双能CTA中,300 mgI/kg对比剂联合40 keV单能图像与ASIR可维持图像质量。
  • 40 keV图像在低剂量组显示与常规70 keV图像相似的强化程度和CNR。
  • 低剂量组40 keV图像SNR更高,但主观评分略低于常规70 keV图像。

局限性

  • 样本量较小(共40例),可能影响统计效能。
  • 单中心研究,结果外推需谨慎。
  • 仅评估了肾脏CTA,未涉及其他血管区域。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To evaluate the value of using low energy (keV) images in renal dual-energy spectral CT angiography (CTA) and adaptive statistical iterative reconstruction (ASIR) to reduce contrast medium dose.

METHODS: 40 patients with renal CTA on a Discovery CT750HD were randomly divided into two groups: 20 cases (Group A) with 600 mgI kg-1 and 20 cases (Group B) with 300 mgI kg-1. The scan protocol for both groups was: dual-energy mode with mA selection for noise index of 10 HU, pitch 1.375:1, rotating speed 0.6 s/r. Images were reconstructed at 0.625 mm thickness with 40%ASIR, Group A used the conventional 70keV monochromatic images, and Group B used monochromatic images from 40 to 70 keV at 5 keV interval for analysis. The CT values and standard deviation (SD) values of the renal artery and erector spine in the plain and arterial phases were measured with the erector spine SD value representing image noise. The enhancement degree of the renal artery (ΔCT = CT(arterial) -CT(plain)), signal-to-noise ratio (SNR=CTrenal-artery/SDrenal-artery) and contrast-to-noise ratio (CNR=(CTrenal-artery-CTerector spine)/SDerector-spine) were calculated. The single factor analysis of variance was used to analyze the difference of ΔCT, SNR and CNR among image groups with p < 0.05 being statistically significant. The subjective image scores of the groups were assessed blindly by two experienced physicians using a 5-point system and the score consistency was compared by the κ test.

RESULTS: Contrast medium dose in the 300 mgI kg-1 group was reduced by 50% compared with the 600 mgI kg-1 group, while radiation dose was similar between the two groups. The subjective scores were 4.00 ± 0.65, 4.50 ± 0.60 and 3.70 ± 0.80 for images at 70 keV (600 mgI kg-1 group), 40 keV (300 mgI kg-1 group) and 45 keV (300 mgI kg-1 group), respectively with good consistency between the two reviewers (p > 0.05). The 40 keV images in the 300 mgI kg-1 group had similar ΔCT (469.77 ± 86.95 HU vs 398.54 ± 73.68 HU) and CNR (15.52 ± 3.32 vs 18.78 ± 6.71) values as the 70 keV images in the 600 mgI kg-1) group but higher SNR values (30.19 ± 4.41 vs 16.91 ± 11.12, p < 0,05).

CONCLUSION: Contrast dose may be reduced by 50% while maintaining image quality by using lower energy images combined with ASIR in renal dual-energy CTA.

ADVANCES IN KNOWLEDGE: Combined with ASIR and energy spectrum, can reduce the amount of contrast dose in renal CTA.

来源:Br J Radiol,查看原文。版权归原作者所有。