腰椎退变性椎间盘病变:常规快速自旋回波T2WI与T2 FSE Dixon序列对比
研究纳入50例腰椎MRI患者,比较常规三序列方案(T1W TSE、T2W FSE、STIR)与单次采集T2W FSE Dixon序列对腰椎退变性椎间盘病变分级、Modic终板改变及高信号区的评估。结果显示Dixon序列在观察者间一致性上与常规方案相当或略优,提示单序列Dixon可能替代常规三序列方案,节省约60%时间。
要点
- 单次矢状面T2W FSE Dixon序列可同时评估椎间盘退变分级、Modic改变和高信号区。
- Dixon序列对Modic终板改变的观察者间一致性略优于常规序列。
- Dixon方案有望替代常规三序列方案,节省约60%扫描时间。
诊断标准与关键数值
- 椎间盘退变分级观察者间一致性:常规方案0.57,Dixon方案0.63(p=0.08)。
- Modic终板改变观察者间一致性:常规方案0.45,Dixon方案0.53(p=0.02)。
- 高信号区识别观察者间一致性:常规方案0.52,Dixon方案0.46(p=0.27)。
- 序列间一致性:椎间盘退变分级0.61-0.97,Modic改变0.46-0.62,高信号区0.39-0.5。
局限性
- 样本量较小(50例),年龄范围8-82岁,可能影响结果外推。
- 研究为单中心设计,仅对比序列间一致性,未评估诊断准确性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To compare the grading of lumbar degenerative disc disease (DDD), Modic end-plate changes (MEPC) and identification of high intensity zones (HIZ) on a combination of sagittal T1weighted turbo spin echo (T1W TSE), T2weighted fast spin echo (T2W FSE) and short tau inversion recovery (STIR) sequences (routine protocol) with a single sagittal T2W FSE Dixon MRI sequence which provides in-phase, opposed-phase, water only and fat only images in a single acquisition (Dixon protocol).
METHODS: 50 patients underwent lumbar spine MRI using the routine protocol with the addition of a T2W FSE Dixon sequence. DDD grade, MEPC and HIZ for each disc level were assessed on the routine and Dixon protocols. Each protocol was reviewed independently by three readers (consultant musculoskeletal radiologists with 26-, 8- and 4 years' experience), allowing assessment of inter-reader agreement and inter protocol agreement for each assessed variable.
RESULTS: The study included 17 males and 33 females (mean age 51 years; range 8-82 years). Inter-reader agreement for DDD grade on the routine protocol was 0.57 and for the Dixon protocol was 0.63 (p = 0.08). Inter-reader agreement for MEPC on the routine protocol was 0.45 and for the Dixon protocol was 0.53 (p = 0.02), and inter-reader agreement for identification of the HIZ on the routine protocol was 0.52 and for the Dixon protocol was 0.46 (p = 0.27). Intersequence agreement for DDD grade ranged from 0.61 to 0.97, for MEPC 0.46-0.62 and for HIZ 0.39-0.5.
CONCLUSION: A single sagittal T2W FSE Dixon MRI sequence could potentially replace the routine three sagittal sequence protocol for assessment of lumbar DDD, MEPC and HIZ resulting in ~60% time saving.
ADVANCES IN KNOWLEDGE: Grading of lumbar DDD, presence of Modic changes and high intensity zones were compared on sagittal T1W TSE, T2W FSE and STIR sequences with a T2W FSE Dixon sequence, with fair-to-good correlation suggesting that three conventional sequences could be replaced by a single Dixon sequence.
引用
- Saifuddin A, Rajakulasingam R, Santiago R, et al. Comparison of lumbar degenerative disc disease using conventional fast spin echo T2W MRI and T2 fast spin echo dixon sequences. Br J Radiol. 2021. PMID: 33684306. doi:10.1259/bjr.20201438
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。