文献速递骨肌MRCT

T1加权脂肪抑制MRI提高骶髂关节软骨下侵蚀检出

Improved detection of subchondral erosions in the sacroiliac joints with T1-weighted fat-suppressed MRI.
PubMed 文献 · Eur Radiol · 2021-03-19

回顾性纳入31例疑似或确诊中轴型脊柱关节炎患者,以MDCT为参考标准,比较标准T1w无脂肪抑制与T1w联合脂肪抑制MRI对骶髂关节软骨下侵蚀的诊断性能差异。结果显示加用脂肪抑制后敏感度、特异度、阳性预测值及总体准确率均显著提高。

要点

  • 阅片时应加用T1w脂肪抑制序列以提高骶髂关节软骨下侵蚀检出。
  • T1w脂肪抑制可增加关节腔高信号与邻近软骨下骨低信号的对比。
  • 阳性预测值提升明显,有助于减少侵蚀的假阳性诊断。

关键影像表现/征象

  • T1w脂肪抑制可增加关节腔高信号与邻近软骨下骨低信号的对比,有助于显示侵蚀。

诊断标准与关键数值

  • 加用T1w脂肪抑制后敏感度R1为76%、R2为70%,无脂肪抑制时分别为63%、60%。
  • 特异度R1为97%、R2为96%,无脂肪抑制时分别为84%、81%。
  • 阳性预测值R1为85%、R2为81%,无脂肪抑制时分别为45%、40%。
  • 总体准确率R1为94%、R2为92%,无脂肪抑制时分别为80%、77%。

临床应用与阅片要点

  • 在骶髂关节MRI方案中纳入T1w脂肪抑制序列,以辅助侵蚀检出和报告。
  • 判读侵蚀时注意结合脂肪抑制图像区分关节腔与软骨下骨信号。

局限性

  • 回顾性设计,样本量较小(31例),结论需更大样本验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To compare the diagnostic performance of two different sets of magnetic resonance imaging (MRI) for the detection of subchondral erosions in the sacroiliac joints regarding the application of fat-water separation techniques when acquiring T1-weighted (T1w) images, using multi-detector computed tomography (MDCT) as the reference standard.

METHODS: We retrospectively included 31 consecutive patients having or being suspected for axial spondyloarthritis (SpA) assessed using both MRI and MDCT. Three sets of images were independently assessed for the presence of erosions by two musculoskeletal radiologists (R1, R2): (1) MRI with standard T1w without fat suppression, (2) MRI with both T1w with and without fat suppression, and (3) MDCT. The diagnostic performance of both sets of MRIs was assessed using MDCT as the referent.

RESULTS: The assessment of T1w images with fat suppression substantially increased sensitivity (76% vs. 63% R1; 70% vs. 60% R2), specificity (97% vs. 84% R1; 96% vs. 81% R2), positive predictive value (85% vs. 45% R1; 81% vs. 40% R2), and overall accuracy (94% vs. 80% R1; 92% vs. 77% R2) in the detection of erosions when compared to the assessment using T1w images without fat suppression.

CONCLUSION: The assessment of T1w images with fat suppression substantially improves the diagnostic performance of MRI in the detection of erosions in the sacroiliac joints.

KEY POINTS: • The presence of erosions in the sacroiliac joints may influence the decision on the diagnosis of axial spondyloarthritis. • T1w fat-suppressed MR imaging relatively increases the contrast between the joint space (high signal) and the adjacent subchondral bone (low signal), potentially improving the detection of erosions in the sacroiliac joints. • T1w fat-suppressed images improve the diagnostic performance of MRI in the detection of erosions in the sacroiliac joints compared to T1w without fat suppression, using MDCT as the reference.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Crema MD, Miquel A, Gouvion A, et al. Improved detection of subchondral erosions in the sacroiliac joints with T1-weighted fat-suppressed MRI. Eur Radiol. 2021. PMID: 33740094. doi:10.1007/s00330-021-07785-1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。