冠状位胫股半脱位的测量策略:系统综述
该系统综述按PRISMA指南检索PubMed,最终纳入16篇文献,分析冠状位胫股半脱位在X线影像上的测量与计算方法。文献中使用的影像视图、解剖标志和测量效度差异较大,全下肢X线视图最常用,是否用胫骨平台宽度校正膝尺寸存在争议。作者认为需进一步研究以标准化可重复、低偏倚的测量方法。
要点
- 全下肢X线视图是测量冠状位胫股半脱位最常用的影像视图。
- 文献中测量方法包括胫骨与股骨机械轴平移、股骨髁相对胫骨平台平移及基于坐标的迭代最近点算法。
- 是否用胫骨平台宽度校正膝尺寸存在争议,测量方法尚未标准化。
诊断标准与关键数值
- 6项研究测量胫骨与股骨机械轴的平移。
- 8项研究测量任一 femoral condyle 相对于胫骨平台的平移。
- 2项研究使用基于坐标的软件结合迭代最近点算法。
- 全下肢X线视图是最常用的影像视图。
局限性
- 原文未述局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE. Coronal tibiofemoral (TF) subluxation has generated interest in the last several years due to newfound clinical implications of its presence. However, controversy within the literature concerning how to measure and calculate coronal TF subluxation on radiographic imaging remains. The purpose of this study was to describe how coronal TF subluxation is being measured and calculated in the literature with the goal of describing a reproducible and validated technique for clinical adoption. MATERIALS AND METHODS. A PubMed literature search was performed in March 2020 according to PRISMA guidelines. The terms "tibiofemoral subluxation" and "tibial femoral subluxation" were included in the search. Criteria of interest included radiographic view and evaluation, anatomic landmarks used, and measurement validity. RESULTS. Review of relevant literature resulted in 744 articles, 16 of which met our inclusion criteria. A wide range of measuring techniques, anatomic landmarks, and radiographic views were used with varying validity. Full-limb radiographic views were the most common. Six studies measured the translation of the mechanical axes of the tibia and femur. Eight studies measured the translation of either femoral condyle in reference to the tibial plateau. Coordinate-based software with the iterative closest point algorithm was used in two studies. Whether coronal TF subluxation should be divided by tibial plateau width to account for knee size was controversial. CONCLUSION. A variety of approaches exist for diagnosing and quantifying coronal TF subluxation because of the lack of clear anatomic landmarks within the TF joint that can be used to measure coronal TF subluxation in the horizontal plane. Even when using the same anatomic landmarks, studies varied on how to measure coronal TF subluxation radiographically and whether knee size should be accounted for. Further studies are necessary to standardize (via inter- and intraobserver validation with a control group) an easy, reproducible, and minimally biased approach to measuring coronal TF subluxation on radiographic imaging. We believe our systematic review succinctly provides the necessary information to either develop such a tool or encourage future studies to compare existing techniques to find the most reliable and clinically useful approach for evaluating coronal TF subluxation.
引用
- Greif DN, Epstein AL, Hodgens BH, et al. Current Measurement Strategies of Coronal Tibiofemoral Subluxation: A Systematic Review of Literature. AJR Am J Roentgenol. 2021. PMID: 33729875. doi:10.2214/AJR.20.23503
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。