文献速递甲状腺与浅表US

DTD-TIRADS诊断弥漫性甲状腺疾病的效能与观察者间一致性验证

Validation of Diagnostic Performance and Interobserver Agreement of DTD-TIRADS for Diffuse Thyroid Disease on Ultrasound: A Single-Center Study.
PubMed 文献 · AJR Am J Roentgenol · 2021-03-03

本回顾性单中心研究纳入180例术前行甲状腺超声的患者,由三名放射科医师盲法按四类DTD-TIRADS分类系统独立评估超声特征。以病理结果为参考,DTD-TIRADS诊断弥漫性甲状腺疾病的ROC曲线下面积在三名医师间无显著差异,诊断切点为III类,观察者间一致性几乎完美(κ=0.81)。结论认为DTD-TIRADS具有高诊断效能和几乎完美的观察者间一致性,可视为诊断弥漫性甲状腺疾病的有效分类系统。

要点

  • DTD-TIRADS以III类为诊断切点,敏感度83.8%-86.5%、特异度81.1%-83.2%。
  • 三名医师间DTD-TIRADS分类一致性几乎完美(κ=0.81)。
  • 三名医师的ROC曲线下面积无显著差异(p > .05)。

局限性

  • 原文未述局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE. This retrospective study aimed to investigate the capability of the already-proposed thyroid imaging reporting and data system for detecting diffuse thyroid disease (DTD-TIRADS) on ultrasound (US) by assessing interobserver agreement and diagnostic performance. MATERIALS AND METHODS. A total of 180 patients who underwent thyroid US before thyroid surgery were included. Three radiologists blinded to the pathologic and serologic data independently categorized the US features according to a four-category DTD-TIRADS classification system. On the basis of the pathologic results of thyroid parenchyma, diagnostic performance values were calculated using ROC curve analyses. Interobserver agreements of each US feature and DTD-TIRADS category among the three radiologists were also assessed. RESULTS. Of the 180 patients, 143 (79.4%) had normal thyroid parenchyma and 37 (20.6%) had diffuse thyroid disease (DTD). The areas under the ROC curve for DTD were not significantly different among the three radiologists: 0.876 (95% CI, 0.819-0.920) for radiologist 1, 0.883 (95% CI, 0.827-0.926) for radiologist 2, and 0.861 (95% CI, 0.801-0.908) for radiologist 3 (p > .05). The cutoff for the diagnosis of DTD was category III DTD-TIRADS. The sensitivity, specificity, and accuracy of DTD-TIRADS for detecting DTD were 86.5%, 81.1%, and 82.2% for radiologist 1; 86.5%, 83.2%, and 83.9% for radiologist 2; and 83.8%, 82.5%, and 82.8% for radiologist 3, respectively. Interobserver agreement of DTD-TIRADS categorization was almost perfect (κ = 0.81). CONCLUSION. DTD-TIRADS has high diagnostic performance and almost-perfect interobserver agreement. Thus, DTD-TIRADS can be considered to be an effective classification system for diagnosing DTD.

来源:AJR Am J Roentgenol,查看原文。版权归原作者所有。

引用

  1. Baek HJ, Ryu KH, An HJ, et al. Validation of Diagnostic Performance and Interobserver Agreement of DTD-TIRADS for Diffuse Thyroid Disease on Ultrasound: A Single-Center Study. AJR Am J Roentgenol. 2021. PMID: 33655773. doi:10.2214/AJR.20.23231

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。