双能CT定量参数联合形态学特征术前预测甲状腺乳头状癌颈部淋巴结转移
静脉期归一化碘浓度诊断转移淋巴结敏感度62.5%、特异度85.7%;短径>5 mm标准敏感度86.3%、特异度69.8%。联合定量与形态学参数AUC达0.878,显著优于任一单一参数。
要点
- 静脉期归一化碘浓度诊断转移淋巴结敏感度低(62.5%)但特异度高(85.7%)。
- 短径>5 mm标准敏感度高(86.3%)但特异度较低(69.8%)。
- 联合定量DECT参数与全部形态学数据AUC 0.878,敏感度87.5%,特异度73.8%。
关键影像表现/征象
- 转移性与良性淋巴结的定量DECT参数及定性形态学特征被独立分析。
- 静脉期归一化碘浓度是DECT最佳单一参数,诊断转移淋巴结敏感度62.5%、特异度85.7%。
- 形态学最佳单一标准为最短径>5 mm,敏感度86.3%、特异度69.8%。
诊断标准与关键数值
- 静脉期归一化碘浓度诊断转移性颈部淋巴结的敏感度62.5%、特异度85.7%。
- 最短径>5 mm诊断转移性颈部淋巴结的敏感度86.3%、特异度69.8%。
- 静脉期归一化碘浓度联合最短径>5 mm的AUC 0.846、敏感度86.3%、特异度72.2%。
- 多个定量DECT参数联合全部形态学数据的AUC 0.878、敏感度87.5%、特异度73.8%。
临床应用与阅片要点
- 术前评估甲状腺乳头状癌颈部淋巴结时,可结合静脉期归一化碘浓度与淋巴结最短径>5 mm提高诊断准确性。
局限性
- 原文未述局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE. The purpose of our study was to assess the value of combining quantitative dual-energy CT (DECT) parameters with qualitative morphologic parameters for the preoperative prediction of cervical nodal metastasis from papillary thyroid carcinoma (PTC). MATERIALS AND METHODS. Thirty-five patients with pathologically proven PTC underwent single-phase contrast-enhanced DECT before thyroidectomy and cervical lymphadenectomy. Analyses of quantitative DECT parameters and qualitative morphologic features of metastatic and benign lymph nodes (LNs) were independently performed. The diagnostic performances of using only quantitative parameters, only morphologic features, and their combination for predicting cervical nodal metastasis were statistically calculated with ROC curves and logistic regression models. RESULTS. A total of 206 LNs, 80 metastatic and 126 benign, were included. The best single performer in DECT was the normalized iodine concentration in the venous phase, which had low sensitivity (62.5%) but high specificity (85.7%), for diagnosing metastatic cervical LNs. On the other hand, the best single performer in qualitative morphologic parameters was using the criterion of shortest diameter of greater than 5 mm, which had low specificity (69.8%) but high sensitivity (86.3%). Combining these two parameters improved the AUC, sensitivity, and specificity to 0.846, 86.3%, and 72.2%, respectively. The combination of multiple quantitative DECT parameters and all morphologic data further improved AUC, sensitivity, and specificity to 0.878, 87.5%, and 73.8%, respectively, which was significant compared with the use of any single parameter. CONCLUSION. The combination of quantitative DECT parameters with morphologic data improves performance in the preoperative diagnosis of metastatic cervical LNs in patients with PTC.
引用
- Wu YY, Wei C, Wang CB, et al. Preoperative Prediction of Cervical Nodal Metastasis in Papillary Thyroid Carcinoma: Value of Quantitative Dual-Energy CT Parameters and Qualitative Morphologic Features. AJR Am J Roentgenol. 2021. PMID: 33760651. doi:10.2214/AJR.20.23516
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。