弹性成像与多普勒超声可能改变TIRADS分类并提升诊断效能
该前瞻性研究纳入210例甲状腺结节患者,评估常规超声、剪切波弹性成像(SWE)和多普勒超声(DUS)表现,并按Kwak、ACR及EU-TIRADS分类,同时构建新评分系统。新系统在ROC分析中敏感度、特异度、PPV、NPV、准确率及AUC均最高。结论提示SWE和DUS表现可能改变TIRADS分类并提高诊断效能。
要点
- 新评分系统较Kwak、ACR、EU-TIRADS的敏感度、特异度、PPV、NPV、准确率及AUC均最高。
诊断标准与关键数值
- 新评分系统在ROC曲线分析中敏感度、特异度、PPV、NPV、准确率及AUC均高于Kwak TIRADS、ACR TIRADS和EU-TIRADS。
临床应用与阅片要点
- 在常规超声TIRADS分类基础上,可结合SWE的Emean值和DUS的RI值辅助评估甲状腺结节。
- 新评分系统在研究中显示较现有TIRADS更高的敏感度、特异度、PPV、NPV、准确率及AUC,但需注意其标准由本研究定义。
局限性
- 原文未述局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVES: The main aim of ultrasonography (US) examining thyroid nodules is to differentiate malignant nodules from benign nodules. Several professional societies and groups of investigators have defined guidelines such as Thyroid Imaging Reporting and Data System (TIRADS) to provide the standardized language and approach to thyroid nodules. This study is aimed to investigate the compatibility of such classification systems with the pathological diagnosis of nodules and evaluate the contribution of the Shear-wave elastography (SWE) and Doppler ultrasonography (DUS) findings.
MATERIALS AND METHODS: This is a prospective study. Patients with thyroid US exams between December 2017 and April 2019 were included. In the study, eligible 210 nodules from 210 patients were enrolled. For stratification, the conventional B-mode US, SWE and DUS were performed. According to Kwak, American College of Radiology (ACR), and European (EU)-TIRADS, Nodules were classified separately, and a new scoring system whose the criteria was put defined in the study has developed.
RESULTS: For SWE; Emean cut-off value was 33 kPa with a sensitivity and specificity of 95,6% (95% CI: 0,85-0,98) and 95% (95% CI:0,90-0,97) respectively (p <0.001). For spectral DUS; resistivity index (RI) cut-off value was 0.64 with a sensitivity and specificity of 73,3% (95% CI:0,59-0,83) and 80% (95% CI:0,73-0,85) respectively (p <0.001). Kwak TIRADS, American College of Radiology TIRADS, EU-TIRADS, and new system were compared by ROC curve analysis. The new system has the highest sensitivity, specificity, PPV, NPV, accuracy, and AUC compared to others.
CONCLUSIONS: The new scoring system has shown that SWE and DUS findings may alter the categorization in TIRADS and increase sensitivity and specificity.
引用
- Baş H, Üstüner E, Kula S, et al. Elastography and Doppler May Bring a New Perspective to TIRADS, Altering Conventional Ultrasonography Dominance. Acad Radiol. 2021. PMID: 33726964. doi:10.1016/j.acra.2021.02.011
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。