Kaiser评分在乳腺MRI病灶定性中的诊断效能及其与多参数分类系统的比较

Diagnostic performance of the Kaiser score for characterizing lesions on breast MRI with comparison to a multiparametric classification system.
PubMed 文献 · Eur J Radiol · 2021-03-16

该研究纳入499例连续患者共697个经组织病理学验证的乳腺病灶,在3.0T MRI上由两名不知临床和病理信息的放射科医生分别评估Kaiser评分和基于BI-RADS的多参数分类系统(MCS)。Kaiser评分诊断准确率高、观察者间可重复性极好,MCS敏感度完美但特异度低;Kaiser评分敏感度略低但特异度为MCS的3–4倍,可能显著降低真阴性病灶的活检率。

要点

  • Kaiser评分观察者间ICC为0.882,可重复性极好。
  • MCS敏感度100%、特异度12%;Kaiser评分敏感度98.5%–98.7%、特异度34.8%–47.5%。
  • 应用Kaiser评分可使158个良性病灶的活检率分别降低22.8%(读者1)和35.4%(读者2)。

诊断标准与关键数值

  • MCS鉴别良恶性病灶的敏感度100%、特异度12%。
  • Kaiser评分鉴别良恶性病灶:读者1敏感度98.5%、特异度34.8%;读者2敏感度98.7%、特异度47.5%。
  • Kaiser评分ROC曲线下面积:读者1为85.9,读者2为87.6。
  • 观察者间组内相关系数为0.882。
  • 读者1将6个病灶从BI-RADS 3升级至Kaiser评分>4,读者2升级7个病灶。

临床应用与阅片要点

  • 对158个良性病灶应用Kaiser评分,读者1和读者2分别可使活检率降低22.8%和35.4%。
  • Kaiser评分与MCS相比敏感度略低但特异度为MCS的3–4倍,可能有助于减少真阴性病灶的活检。

局限性

  • 原文未述局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To determine the diagnostic performance of the Kaiser score and to compare it with the BI-RADS-based multiparametric classification system (MCS).

METHOD: Two breast radiologists, blinded to the clinical and pathological information, separately evaluated a database of 499 consecutive patients with structural 3.0 T breast MRI and 697 histopathologically verified lesions. The Kaiser scores and corresponding MCS categories were recorded. The sensitivity and specificity of the Kaiser score and the MCS categories to differentiate benign from malignant lesions were calculated. The interobserver reproducibility and receiver operating characteristic (ROC) parameters were analysed.

RESULTS: The sensitivity and specificity of the MCS were 100 % and 12 %, respectively, and those of the Kaiser score were 98.5 % and 34.8 % for reader 1 and 98.7 % and 47.5 % for reader 2. The area under the ROC-curve was 85.9 and 87.6 for readers 1 and 2. The interobserver intraclass correlation coefficient was excellent at 0.882. Reader 1 upgraded six lesions from BI-RADS 3 to a Kaiser score of >4, and reader 2 upgraded seven lesions. When applying the Kaiser score to 158 benign lesions readers 1 and 2 would have reduced the biopsy rate by 22.8 % and 35.4 %, respectively.

CONCLUSIONS: The Kaiser score showed high diagnostic accuracy with excellent interobserver reproducibility. The MCS had perfect sensitivity but low specificity. Although the Kaiser score had slightly lower sensitivity, its specificity was 3-4 times greater than that of the MCS. Thus, the Kaiser score has the potential to considerably reduce the biopsy rate for true negative lesions.