3T乳腺MRI:同时多层单次激发DWI与分段读出DWI的对比
研究纳入26例组织学证实的乳腺癌患者,在3T MRI上同期采集传统rs-EPI与原型SMS-ss-EPI DWI,4名乳腺放射科医生对25例图像质量、伪影、病灶可见性及BI-RADS评分进行独立评估。结果显示rs-EPI整体图像质量更优且伪影更少,但SMS-ss-EPI上病灶可见性更好,恶性病变更明显,两序列敏感度和特异度相当。
要点
- SMS-ss-EPI上病灶可见性优于rs-EPI(AUCVGC 0.427,P=0.016),恶性病变更明显(P=0.035)。
- rs-EPI整体图像质量更优(AUCVGC 0.698,P=0.002),折叠和鬼影及变形伪影更少。
- 两序列敏感度和特异度无显著差异(P=0.760和P=0.549)。
关键影像表现/征象
- rs-EPI整体图像质量评分显著优于SMS-ss-EPI(AUCVGC 0.698,P=0.002)。
- rs-EPI上折叠和鬼影伪影显著少于SMS-ss-EPI(AUCVGC 0.660,P=0.022)。
- rs-EPI上变形伪影显著少于SMS-ss-EPI(AUCVGC 0.700,P=0.002)。
- SMS-ss-EPI上病灶可见性显著优于rs-EPI(AUCVGC 0.427,P=0.016)。
- SMS-ss-EPI上恶性病灶可见性显著更高(P=0.035)。
诊断标准与关键数值
- 图像质量评分1分(极差)至9分(极好),伪影评分1分(非常干扰)至5分(无伪影)。
- 病灶可见性评分1分(不可见)、2分(给出位置可见)、3分(可见)。
- rs-EPI与SMS-ss-EPI敏感度和特异度相当(P=0.760和P=0.549)。
临床应用与阅片要点
- SMS-ss-EPI可能有助于提高乳腺恶性病灶的可见性,但需注意其图像质量较低和伪影较多。
- rs-EPI图像质量更优、伪影更少,但病灶可见性不如SMS-ss-EPI。
- 判读SMS-ss-EPI图像时需考虑折叠和鬼影及变形伪影对图像质量的影响。
局限性
- 原文未述局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To compare diffusion-weighted imaging of the breast performed with a conventional readout-segmented echo-planar imaging (rs-EPI) sequence to when using a prototype simultaneous multi-slice single-shot EPI (SMS-ss-EPI) acquisition.
METHOD: From September 2017 to December 2018, 26 women with histologically proven breast cancer were scanned with the conventional rs-EPI and the SMS-ss-EPI at 3 T during the same imaging examination. Four breast radiologists (4-13 years of experience) independently scored both acquired series of 25 women (one case was used for training) for overall image quality (1: extremely poor to 9: excellent) and artifacts (1: very disturbing to 5: not present). All lesions (n = 52; 40 malignant, 12 benign) were also evaluated for visibility (1: not visible, 2: visible if location is given, 3: visible). In addition, lesion characteristics were rated, and a BI-RADS score was given. Results were analyzed using visual grading characteristics and the resulting area under the curve (AUCVGC), weighted kappa, McNemar test, and dependent-samples t-test when appropriate.
RESULTS: Overall, radiologists significantly preferred the image quality in rs-EPI over that of SMS-ss-EPI (AUCVGC: 0.698, P = 0.002). Infolding and ghosting, and distortion artifacts were significantly less apparent in the rs-EPI (AUCVGC: 0.660, P = 0.022 and AUCVGC: 0.700 P = 0.002, respectively). Lesions were, however, significantly better visible on the SMS-ss-EPI images (AUCVGC: 0.427, P = 0.016). Malignant lesions had significantly higher visibility with SMS-ss-EPI (P = 0.035). Sensitivity and specificity were comparable between both sequences (P = 0.760 and P = 0.549, respectively).
CONCLUSIONS: Despite the perceived lower image quality and the increased presence of artifacts in the SMS-ss-EPI sequence, malignant lesions are better visualized using this sequence.
引用
- Sanderink WBG, Teuwen J, Appelman L, et al. Comparison of simultaneous multi-slice single-shot DWI to readout-segmented DWI for evaluation of breast lesions at 3T MRI. Eur J Radiol. 2021. PMID: 33711569. doi:10.1016/j.ejrad.2021.109626
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。