文献速递乳腺乳腺X线

AI-CAD在乳腺断层合成合成乳腺X线摄影与数字乳腺X线摄影中的对比研究

Application of artificial intelligence-based computer-assisted diagnosis on synthetic mammograms from breast tomosynthesis: comparison with digital mammograms.
PubMed 文献 · Eur Radiol · 2021-03-12

该回顾性研究纳入192例患者共203个乳腺癌,比较商用AI-CAD在数字乳腺X线摄影(DM)与断层合成重建的合成乳腺X线摄影(SM)上的异常评分一致性与诊断性能。结果显示SM与DM异常评分一致性高(一致性相关系数0.934),诊断性能无显著差异(AUC 0.945 vs 0.938,p=0.499),SM在伴有结构扭曲、隐匿性表现、T1、N0及Luminal型癌症中异常评分更高。

要点

  • AI-CAD在SM与DM上诊断性能相当,AUC分别为0.938与0.945(p=0.499),SM可替代DM用于AI-CAD分析。
  • SM与DM的AI-CAD异常评分一致性高,一致性相关系数0.934(95%CI 0.92,0.946),平均偏差-3.26。
  • SM在结构扭曲、隐匿性表现、T1、N0及Luminal型癌症中异常评分高于DM(均p≤0.001)。

局限性

  • 原文未述局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To compare the diagnostic agreement and performances of synthetic and conventional mammograms when artificial intelligence-based computer-assisted diagnosis (AI-CAD) is applied.

MATERIAL AND METHOD: From January 2017 to April 2017, 192 patients (mean age 53.7 ± 11.7 years) diagnosed with 203 breast cancers were enrolled in this retrospective study. All patients underwent digital breast tomosynthesis (DBT) with digital mammograms (DM) simultaneously. Commercial AI-CAD was applied to the reconstructed synthetic mammograms (SM) from DBT and DM respectively and abnormality scores were calculated. We compared the median abnormality scores between DM and SM with the Wilcoxon signed-rank test and used the Bland-Altman analysis to evaluate agreements between the two mammograms and to investigate clinicopathological factors which might affect agreement. Diagnostic performances were compared using an area under the receiver operating characteristic curve (AUC).

RESULT: The abnormality scores showed a mean difference (bias) of - 3.26 (95% limits of agreement: - 32.69, 26.18) between the two mammograms by the Bland-Altman analysis. The concordance correlation coefficient was 0.934 (95% CI: 0.92, 0.946), suggesting high reproducibility. SM showed higher abnormality scores in cancer with distortion and occult findings, T1 and N0 cancer, and luminal type cancer than DM (all p ≤ 0.001). Diagnostic performance did not differ between the mammograms (AUC 0.945 for conventional mammograms, 0.938 for synthetic mammograms, p = 0.499).

CONCLUSION: AI-CAD can also work well on synthetic mammograms, showing good agreement and comparable diagnostic performance compared to its application to DM.

KEY POINTS: • AI-CAD which was developed based on imaging findings of digital mammograms can also be applied to synthetic mammograms. • AI-CAD showed good agreement and similar diagnostic performance when applied to both synthetic and digital mammograms. • With AI-CAD, synthetic mammograms showed relatively higher abnormality scores in cancer with distortion and occult findings, T1 and N0 cancer, and luminal type cancer than digital mammograms.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Lee SE, Han K, Kim EK, et al. Application of artificial intelligence-based computer-assisted diagnosis on synthetic mammograms from breast tomosynthesis: comparison with digital mammograms. Eur Radiol. 2021. PMID: 33710372. doi:10.1007/s00330-021-07796-y

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。