高空间分辨率多激发多重敏感编码扩散加权成像提升乳腺图像质量及鉴别乳腺病变的可行性研究
MUSE DWI在体模和患者中均显著改善图像质量(SNR、CNR),ADC值在良恶性病变间有显著差异,但两种DWI序列的平均、最大、最小ADC值无显著差异。MUSE DWI视觉评估病灶可见性优于单激发DWI(κ=0.70)。
要点
- MUSE DWI较单激发DWI显著提高病灶SNR(P=.009)、纤维腺体组织SNR(P=.05)和CNR(P=.008)。
- MUSE DWI的ADC值在乳腺良恶性病变间有显著差异(P<.001),可用于病变鉴别。
- MUSE DWI与单激发DWI的平均、最大、最小ADC值无显著差异(P分别为.96、.28、.49)。
关键影像表现/征象
- MUSE DWI在体模中SNR显著优于单激发DWI(P=.001)。
- 患者中MUSE DWI的病灶SNR(P=.009)、纤维腺体组织SNR(P=.05)和CNR(P=.008)均显著优于单激发DWI。
- 视觉定性分析显示MUSE DWI的病灶可见性优于单激发DWI(κ=0.70)。
诊断标准与关键数值
- MUSE DWI的ADC值在恶性与良性病变间有显著差异(P<.001)。
- MUSE DWI与单激发DWI的平均ADC值无显著差异(P=.96)。
- MUSE DWI与单激发DWI的最大ADC值无显著差异(P=.28)。
- MUSE DWI与单激发DWI的最小ADC值无显著差异(P=.49)。
临床应用与阅片要点
- MUSE DWI可作为常规乳腺MRI方案中易实施的序列,提供高质量扩散加权图像。
- 阅片时关注MUSE DWI上病灶可见性及ADC值对良恶性病变的鉴别,但注意其ADC均值与单激发DWI无显著差异。
局限性
- 原文未述局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Multishot multiplexed sensitivity-encoding diffusion-weighted imaging is a feasible and easily implementable routine breast MRI protocol that yields high-quality diffusion-weighted breast images.Purpose: To compare multiplexed sensitivity-encoding (MUSE) diffusion-weighted imaging (DWI) and single-shot DWI for lesion visibility and differentiation of malignant and benign lesions within the breast.Materials and Methods: In this prospective institutional review board-approved study, both MUSE DWI and single-shot DWI sequences were first optimized in breast phantoms and then performed in a group of patients. Thirty women (mean age, 51.1 years ± 10.1 [standard deviation]; age range, 27-70 years) with 37 lesions were included in this study and underwent scanning using both techniques. Visual qualitative analysis of diffusion-weighted images was accomplished by two independent readers; images were assessed for lesion visibility, adequate fat suppression, and the presence of artifacts. Quantitative analysis was performed by calculating apparent diffusion coefficient (ADC) values and image quality parameters (signal-to-noise ratio [SNR] for lesions and fibroglandular tissue; contrast-to-noise ratio) by manually drawing regions of interest within the phantoms and breast tumor tissue. Interreader variability was determined using the Cohen κ coefficient, and quantitative differences between MUSE DWI and single-shot DWI were assessed using the Mann-Whitney U test; significance was defined at P < .05.Results: MUSE DWI yielded significantly improved image quality compared with single-shot DWI in phantoms (SNR, P = .001) and participants (lesion SNR, P = .009; fibroglandular tissue SNR, P = .05; contrast-to-noise ratio, P = .008). MUSE DWI ADC values showed a significant difference between malignant and benign lesions (P < .001). No significant differences were found between MUSE DWI and single-shot DWI in the mean, maximum, and minimum ADC values (P = .96, P = .28, and P = .49, respectively). Visual qualitative analysis resulted in better lesion visibility for MUSE DWI over single-shot DWI (κ = 0.70).Conclusion: MUSE DWI is a promising high-spatial-resolution technique that may enhance breast MRI protocols without the need for contrast material administration in breast screening.Keywords: Breast, MR-Diffusion Weighted Imaging, OncologySupplemental material is available for this article.© RSNA, 2020.
引用
- Daimiel Naranjo I, Lo Gullo R, Morris EA, et al. High-Spatial-Resolution Multishot Multiplexed Sensitivity-encoding Diffusion-weighted Imaging for Improved Quality of Breast Images and Differentiation of Breast Lesions: A Feasibility Study. Radiol Imaging Cancer. 2020. PMID: 33778712. doi:10.1148/rycan.2020190076
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。