自动乳腺超声作为40-49岁东亚女性乳腺癌首选筛查方法的多中心前瞻性研究

Automated breast US as the primary screening test for breast cancer among East Asian women aged 40-49 years: a multicenter prospective study.
PubMed 文献 · Eur Radiol · 2021-03-29

该前瞻性多中心研究纳入959名40-49岁无症状韩国女性,评估自动乳腺超声(ABUS)单独作为首选筛查试验的诊断性能。结果显示召回率9.8%,癌症检出率5.2/1000,敏感度83.3%,特异度90.7%,间期癌仅1例。结论提示在东亚地区,ABUS筛查可能作为乳腺X线筛查的替代方案。

要点

  • ABUS单用筛查40-49岁东亚女性:召回率9.8%,癌症检出率5.2/1000。
  • 敏感度83.3%、特异度90.7%,活检阳性预测值(PPV3)20.0%。
  • 背景回声不均匀者召回率更高、特异度更低;BMI<25 kg/m²者召回率更高。

诊断标准与关键数值

  • 召回率9.8%(95%CI:7.9%,11.7%;94/959)。
  • 癌症检出率5.2/1000(95%CI:-0.6,11.1;5/959)。
  • 敏感度83.3%(95%CI:53.5%,100%;5/6例癌症)。
  • 特异度90.7%(95%CI:88.8%,92.5%;864/959)。
  • 活检阳性预测值(PPV3)20.0%(95%CI:4.3%,35.7%;5/25)。

临床应用与阅片要点

  • ABUS可作为40-49岁东亚女性乳腺癌筛查的可行选项,尤其适用于乳腺X线不宜或不可及的情况。
  • 阅片时需关注背景回声不均匀对召回率和特异度的影响,并注意BMI<25 kg/m²者召回率可能更高。
  • 双读模式有助于保障诊断准确性,活检决策应结合ABUS表现与临床评估。

局限性

  • 原文未述局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To prospectively evaluate the diagnostic performance of screening ABUS as the primary screening test for breast cancer among Korean women aged 40-49 years.

METHODS: This prospective, multicenter study included asymptomatic Korean women aged 40-49 years from three academic centers between February 2017 and October 2019. Each participant underwent ABUS without mammography, and the ABUS images were interpreted at each hospital with double-reading by two breast radiologists. Biopsy and at least 1 year of follow-up was considered the reference standard. Diagnostic performance of ABUS screening and subgroup analyses according to patient and tumor characteristics were evaluated.

RESULTS: Reference standard data were available for 959 women. The recall rate was 9.8% (95% confidence interval [CI]: 7.9%, 11.7%; 94 of 959 women) and the cancer detection yield was 5.2 per 1000 women (95% CI: -0.6, 11.1; 5 of 959 women). There was only one interval cancer. The sensitivity was 83.3% (95% CI: 53.5%, 100%; 5 of 6 cancers) and the specificity was 90.7% (95% CI: 88.8%, 92.5%; 864 of 95. women). The positive predictive values of biopsies performed (PPV3) was 20.0% (95% CI: 4.3%, 35.7%; 5 of 25 women). Women with heterogeneous background echotexture had a higher recall rate (p = .009) and lower specificity (p = .036). Women with body mass index values < 25 kg/m2 had a higher mean recall rate (p = .046).

CONCLUSION: In East Asia, screening automated breast US may be an alternative to screening mammography for detecting breast cancers in women aged 40-49 years.

KEY POINTS: • Automated breast US screening for breast cancer in asymptomatic women aged 40-49 is effective with 5.2 per 1000 cancer detection yield. • Women with heterogeneous background echotexture had a higher recall rate and lower specificity. • Women with body mass index < 25 kg/m2 had a higher recall rate.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Choi WJ, Kim SH, Shin HJ, et al. Automated breast US as the primary screening test for breast cancer among East Asian women aged 40-49 years: a multicenter prospective study. Eur Radiol. 2021. PMID: 33779816. doi:10.1007/s00330-021-07864-3

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。