文献速递乳腺US

人工智能辅助乳腺超声:减少不必要活检的辅助工具

Artificial intelligence for breast ultrasound: An adjunct tool to reduce excessive lesion biopsy.
PubMed 文献 · Eur J Radiol · 2021-03-04

该前瞻性研究对173个可疑乳腺病灶在超声引导下穿刺或真空辅助切除前行常规超声与AI分析,以病理为参考标准,回顾性按BI-RADS 2013词典分类。策略B可避免27例活检但漏诊2例恶性肿瘤,活检率降至37.2%(P<0.05)。结论认为AI辅助乳腺超声可减少不必要活检,推荐误诊率较低的降级策略A。

要点

  • AI降级策略A将BI-RADS 4A病灶活检率从100%降至67.4%,正确避免14例活检。
  • AI降级策略B活检率降至37.2%,但漏诊2例恶性肿瘤。
  • 推荐降级策略A,因其误诊率较低。

核心结论

  • 在乳腺超声中加入AI系统可减少不必要的病灶活检。
  • 推荐采用降级策略A,因其误诊率较低。

研究设计与样本

  • 前瞻性研究,对173个可疑乳腺病灶在超声引导下空心针穿刺活检或真空辅助切除前进行常规超声和AI分析。
  • 常规超声图像按BI-RADS 2013词典和分类进行回顾性审阅。
  • 以组织病理学结果为参考标准,分析AI诊断对减少不必要活检的效果。

关键影像表现/征象

  • 降级策略A:若病灶两个正交切面的AI评估均为可能良性,则降级。
  • 降级策略B:若任一正交切面的AI评估为可能良性,则降级。

诊断标准与关键数值

  • 降级策略A:两个正交切面AI评估均为可能良性时,将BI-RADS 4A降为3类;14例活检被正确避免,4A类病灶活检率从100%降至67.4%(P<0.001)。
  • 降级策略B:任一正交切面AI评估为可能良性时,将BI-RADS 4A降为3类;27例活检可被避免,但漏诊2例恶性肿瘤,活检率降至37.2%(P<0.05,与常规超声和策略A相比)。

临床应用与阅片要点

  • AI可作为乳腺超声的辅助工具,用于对BI-RADS 4A病灶进行降级以减少不必要活检。
  • 降级策略A较策略B误诊率更低,推荐优先采用。

局限性

  • 原文未述局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To determine whether adding an artificial intelligence (AI) system to breast ultrasound (US) can reduce unnecessary biopsies.

METHODS: Conventional US and AI analyses were prospectively performed on 173 suspicious breast lesions before US-guided core needle biopsy or vacuum-assisted excision. Conventional US images were retrospectively reviewed according to the BI-RADS 2013 lexicon and categories. Two downgrading stratifications based on AI assessments were manually used to downgrade the BI-RADS category 4A lesions to category 3. Stratification A was used to downgrade if the assessments of both orthogonal sections of a lesion from AI were possibly benign. Stratification B was used to downgrade if the assessment of any of the orthogonal sections was possibly benign. The effects of AI-based diagnosis on lesions to reduce unnecessary biopsy were analyzed using histopathological results as reference standards.

RESULTS: Forty-three lesions diagnosed as BI-RADS category 4A by conventional US received AI-based hypothetical downgrading. While downgrading with stratification A, 14 biopsies were correctly avoided. The biopsy rate for BI-RADS category 4A lesions decreased from 100 % to 67.4 % (P < 0.001). While downgrading with stratification B, 27 biopsies could be avoided with two malignancies missed, and the biopsy rate would decrease to 37.2 % (P < 0.05, compared with conventional US and stratification A).

CONCLUSION: Adding an AI system to breast US could reduce unnecessary lesion biopsies. Downgrading stratification A was recommended for its lower misdiagnosis rate.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Wang XY, Cui LG, Feng J, et al. Artificial intelligence for breast ultrasound: An adjunct tool to reduce excessive lesion biopsy. Eur J Radiol. 2021. PMID: 33706046. doi:10.1016/j.ejrad.2021.109624

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。