经阴道超声与MRI评估低级别子宫内膜样癌肌层浸润的前瞻性对比研究
单中心前瞻性观察研究纳入156例经内膜取样诊断为子宫内膜样1/2级子宫内膜癌患者,术前分别用经阴道超声(TVS)和MRI以主观印象法和Karlsson法评估肌层浸润,以术后病理为标准。MRI主观印象法特异度显著优于TVS主观印象法(87% vs 73.5%,P<.05),但术中评估特异度(97%)显著优于术前影像。
要点
- MRI主观印象法评估深肌层浸润特异度87%,显著优于TVS主观印象法73.5%(P<.05)。
- TVS主观印象法敏感度75%、特异度73.5%;Karlsson法敏感度65%、特异度70%(P=.54)。
- 术中评估特异度97%,显著优于TVS和MRI的两种方法(P<.05)。
诊断标准与关键数值
- TVS主观印象法检测深肌层浸润的敏感度75%、特异度73.5%;TVS Karlsson法敏感度65%、特异度70%(P=.54)。
- MRI主观印象法检测深肌层浸润的敏感度80%、特异度87%;MRI Karlsson法敏感度70%、特异度71.3%。
- MRI主观印象法特异度显著优于MRI Karlsson法(P=.03)。
- 主观印象法下MRI特异度优于TVS(P<.05),Karlsson法下两者无此差异。
- 术中评估检测深肌层浸润的敏感度75%、特异度97%,特异度显著优于TVS和MRI的两种方法(P<.05)。
局限性
- 原文未述局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To compare the diagnostic accuracy of transvaginal ultrasound (TVS) and magnetic resonance imaging (MRI) for assessing myometrial infiltration (MI) in patients with low grade endometrioid endometrial cancer.
METHODS: Observational prospective study performed at a single tertiary care center from 2016 to 2020, comprising 156 consecutive patients diagnosed by endometrial sampling as having an endometrioid grade 1/grade 2 endometrial cancer. TVS and MRI were performed prior to surgical staging for assessing MI, which was estimated using subjective examiner's impression and Karlsson's method for both TVS and MRI. During surgery, intraoperative assessment of MI was also performed. Definitive pathological study considered as reference standard. Diagnostic accuracy for ultrasound, MRI, and intraoperative biopsy was estimated and compared.
RESULTS: Sensitivity and specificity of TVS for detecting deep MI were 75 and 73.5% for subjective impression and 65 and 70% for Karlsson method, respectively (P = .54). Sensitivity and specificity of MRI for detecting deep MI were 80 and 87% for subjective impression and 70 and 71.3% for Karlsson method. MRI subjective impression showed a significant better specificity than MRI Karlsson method (P = .03). MRI showed better specificity than TVS when subjective impression was considered (P <.05), but not for Karlsson method. Sensitivity and specificity of intraoperative were 75 and 97%, respectively. Intraoperative biopsy showed better specificity than ultrasound and MRI either using examiner's impression or Karlsson method (P <.05).
CONCLUSIONS: MRI revealed a significant higher specificity than TVS when assessing deep myometrial infiltration. However, the intraoperative biopsy offers a significant better diagnostic accuracy than preoperative imaging techniques.
引用
- Gastón B, Muruzábal JC, Lapeña S, et al. Transvaginal Ultrasound Versus Magnetic Resonance Imaging for Assessing Myometrial Infiltration in Endometrioid Low Grade Endometrial Cancer: A Prospective Study. J Ultrasound Med. 2021. PMID: 33780025. doi:10.1002/jum.15708
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。