前列腺MRI磁敏感伪影与PI-RADS 3病变:动态对比增强序列的必要性
回顾性分析5个月内因PSA升高行3T多参数前列腺MRI的连续患者,按PI-RADS v2评分,先以双参数(T2WI+DWI)评估并记录磁敏感伪影,再分析标准多参数(加DCE)。双参数评估中43.5%患者存在伪影,无伪影组中13.3%前列腺需DCE;23.9%的PI-RADS 4-5病变在不用DCE时可能漏诊。
要点
- 双参数评估中43.5%患者存在直肠气体等所致磁敏感伪影,影响DWI判读。
- 无伪影前列腺中仅13.3%因PI-RADS 3病变需加做DCE序列。
- 不用DCE时,23.9%的PI-RADS 4-5前列腺病变可能未被检出。
关键影像表现/征象
- 双参数评估中87例(43.5%)存在直肠气体或其他原因所致磁敏感伪影,113例(56.5%)无伪影。
- 无伪影组中15例患者有外周带PI-RADS 3病变。
- 共102例患者(51%)存在伪影或外周带PI-RADS 3病变,需DCE序列。
诊断标准与关键数值
- 按PI-RADS v2评分,病变分类为PI-RADS 1-2、PI-RADS 3或PI-RADS 4-5。
- 无伪影组中13.3%前列腺需DCE序列。
- 不用DCE时,17个(23.9%)PI-RADS 4-5前列腺病变可能未被检出。
临床应用与阅片要点
- 双参数评估发现磁敏感伪影或外周带PI-RADS 3病变时,需加做DCE序列。
- DWI可正确评估时,仅少数前列腺(13.3%)需DCE,可减少不必要序列。
局限性
- 原文未述局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To assess the need of the dynamic contrast-enhanced (DCE) sequence in addition to T2-weighted imaging (T2-WI) and diffusion-weighted imaging (DWI) for the detection of clinically significant prostate cancer in the presence of artifacts associated with rectal gas (which compromise the diffusion assessment) and/or PIRADS 3 lesions.
METHODS: This retrospective study was approved by the institutional review board; informed consent was not required. Patients referred consecutively over a period of 5 months for elevated PSA underwent multiparametric magnetic resonance imaging (mpMRI). mpMRI was performed using a 3T MRI system without an endorectal coil. The MRI findings were reviewed by two radiologists and were scored according to the Prostate Imaging Reporting and Data System version 2.0 (PI-RADSv2). Any discrepancies were resolved by consensus. For statistical purposes, lesions were classified as PIRADS 1-2, PIRADS 3, or PIRADS 4-5. First, all studies were reviewed using a biparametric assessment (T2-WI + DWI), and the presence or absence of susceptibility artifacts was assessed for each prostate. Subsequently, all images were analyzed using the standard multiparametric approach (T2-WI + DWI + DCE).
RESULTS: The biparametric evaluation (T2-WI + DWI) showed artifacts (due to the presence of rectal gas or other) in 87 patients (43.5%) and no artifacts in 113 patients (56.5%). In the latter group, 15 patients had peripheral zone (PZ) PIRADS 3 lesions. Thus, a total of 102 patients (51%) had artifacts or PZ PIRADS 3 lesions and therefore required DCE. When evaluating the group of prostates without artifacts, 13.3% of prostates required DCE. A total of 17 (23.9%) PIRADS 4-5 prostate lesions would have not been detected without the use of DCE.
CONCLUSION: Biparametric evaluation of the prostate revealed some limitation due to the presence of artifacts or PIRADS 3 PZ lesions. Artifacts were present in almost 44% of our patients, but when the DWI was correctly evaluated, only 13.3% of prostates required DCE.
引用
- Antunes N, Vas D, Sebastia C, et al. Susceptibility artifacts and PIRADS 3 lesions in prostatic MRI: how often is the dynamic contrast-enhance sequence necessary? Abdom Radiol (NY). 2021. PMID: 33683430. doi:10.1007/s00261-021-03011-0
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。