合成DWI评估前列腺索引病灶:b值1500-2000 s/mm²的优化依据
该项回顾性研究纳入92例接受DWI及靶向穿刺活检的前列腺MRI索引病灶患者,用专用软件生成b值1000-3000 s/mm²的合成DWI,定性分析病灶最佳视觉显著性、定量分析背景信号均匀抑制的b值。定性与定量分析所得最佳b值范围分别为1761-1805 s/mm²与1640-1771 s/mm²(读者1)、1835-1895 s/mm²与1705-1841 s/mm²(读者2),两者中位b值差异均小于100 s/mm²,推荐b值1500-2000 s/mm²。
要点
- 合成DWI评估前列腺索引病灶时,背景信号均匀抑制的b值范围对病灶显示最佳。
- 定性最佳视觉显著性与定量背景信号均匀所选b值一致,支持1500-2000 s/mm²。
诊断标准与关键数值
- 读者1定性分析最佳b值95%CI为1761-1805 s/mm²(中位1790 s/mm²),定量分析为1640-1771 s/mm²(中位1705 s/mm²),p=0.003。
- 读者2定性分析最佳b值95%CI为1835-1895 s/mm²(中位1872 s/mm²),定量分析为1705-1841 s/mm²(中位1763 s/mm²),p=0.022。
- 读者1定性及定量最佳b值四分位距分别为1735-1873 s/mm²和1573-1867 s/mm²;读者2分别为1775-1945 s/mm²和1591-1955 s/mm²。
- Bland-Altman图显示定性与定量所选最佳b值平均差异均小于100 s/mm²。
局限性
- 原文未述局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: It is uncertain why a b-value range of 1500-2000 s/mm² is optimal. This study was aimed at qualitatively and quantitatively analyzing the optimal b-value range of synthetic diffusion-weighted imaging (sDWI) for evaluating prostatic index lesions.
MATERIALS AND METHODS: This retrospective study included 92 patients who underwent DWI and targeted biopsy for magnetic resonance imaging (MRI)-suggested index lesions. We generated sDWI at a b-value range of 1000-3000 s/mm² using dedicated software and true DWI data at b-values of 0, 100, and 1000 s/mm². We hypothesized that lesion conspicuity would be best when the background (i.e., MRI-suggested benign prostatic [bP] and periprostatic [pP] regions) signal intensity (SI) is suppressed and becomes homogeneous. To prove this hypothesis, we performed both qualitative and quantitative analyses. For qualitative analysis, two independent readers analyzed the b-value showing the best visual conspicuity of an MRI-suggested index lesion. For quantitative analysis, the readers assessed the b-value showing the same bP and pP region SI. The 95% confidence interval (CI) or interquartile range of qualitatively and quantitatively selected optimal b-values was assessed, and the mean difference between qualitatively and quantitatively selected b-values was investigated.
RESULTS: The 95% CIs of optimal b-values from qualitative and quantitative analyses were 1761-1805 s/mm² and 1640-1771 s/mm² (median, 1790 s/mm² vs. 1705 s/mm²; p = 0.003) for reader 1, and 1835-1895 s/mm² and 1705-1841 s/mm² (median, 1872 s/mm² vs. 1763 s/mm²; p = 0.022) for reader 2, respectively. Interquartile ranges of qualitatively and quantitatively selected optimal b-values were 1735-1873 s/mm² and 1573-1867 s/mm² for reader 1, and 1775-1945 s/mm² and 1591-1955 s/mm² for reader 2, respectively. Bland-Altman plots consistently demonstrated a mean difference of less than 100 s/mm² between qualitatively and quantitatively selected optimal b-values.
CONCLUSION: b-value range showing a homogeneous background signal may be optimal for evaluating prostatic index lesions on sDWI. Our qualitative and quantitative data consistently recommend b-values of 1500-2000 s/mm².
引用
- Cha SY, Kim E, Park SY, et al. Why Is a b-value Range of 1500-2000 s/mm² Optimal for Evaluating Prostatic Index Lesions on Synthetic Diffusion-Weighted Imaging? Korean J Radiol. 2021. PMID: 33660462. doi:10.3348/kjr.2020.0836
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。