文献速递泌尿生殖腹部MR

肿瘤-包膜绝对接触长度诊断前列腺癌包膜外侵犯

The absolute tumor-capsule contact length in the diagnosis of extraprostatic extension of prostate cancer.
PubMed 文献 · Abdom Radiol (NY) · 2021-03-26

结果显示绝对肿瘤-包膜接触长度(ABTCL)准确性高于曲线测量,DCE序列测量最准确,推荐ABTCL截断值15.0 mm(敏感度75.86%、特异度72.09%),ABTCL>15 mm与放射科医生视觉评估均为独立预测因子,两者联合可提高诊断效能。

要点

  • ABTCL诊断EPE的推荐截断值为15.0 mm,敏感度75.86%、特异度72.09%。
  • DCE是测量肿瘤-包膜接触面最准确的序列,ABTCL准确性高于曲线测量。
  • ABTCL>15 mm与放射科医生视觉评估均为EPE独立预测因子,联合可提高诊断效能。

关键影像表现/征象

  • 高Gleason评分(8-9分)、放射科医生视觉评估EPE印象及PI-RADS 5与手术标本EPE显著相关(分别为p=0.014、p<0.001、p<0.001)。
  • EPE患者的ACTCL和ABTCL在所有成像序列上均显著高于无EPE患者(p<0.001至p=0.003)。
  • ABTCL的准确性高于ACTCL;DCE是测量接触界面最准确的序列。

诊断标准与关键数值

  • ABTCL推荐截断值为15.0 mm,诊断EPE的敏感度75.86%、特异度72.09%。
  • 多变量分析显示ABTCL>15 mm(p=0.048)和放射科医生视觉评估印象(p=0.016)是EPE的仅有两个独立预测因子。

临床应用与阅片要点

  • 建议放射科医生在术前MRI视觉评估基础上增加包膜接触长度测量以检出EPE。
  • 测量肿瘤-包膜接触面时优先选用DCE序列,并采用ABTCL(绝对接触长度)而非曲线测量。
  • ABTCL>15 mm可作为提示EPE的参考阈值,结合视觉评估印象可提高诊断效能。

局限性

  • 原文未述局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: Extraprostatic extension (EPE) of prostate cancer is associated with a poor prognosis. The broad-based capsule-tumor interface has been recognized as one of the worrisome imaging features in multiparametric prostate MRI (mpMRI). However, there was significant heterogeneity among the measurement method used in prior studies.

OBJECTIVES: This study's objectives were to investigate and compare the accuracy between the curvilinear and linear measurement, find the optimal cut-off contact surface threshold for the diagnosis of EPE, and assess the benefit of the additional contact surface measurement versus visual assessment alone.

METHODS: The status of EPE in mpMRI and the overall PI-RADS were assessed. The tumor's dimensions, the actual tumor-capsule contact length (ACTCL), and the absolute tumor-capsule contact length (ABTCL) were measured. The parameters were analyzed and correlated with the EPE status from prostatectomy specimens.

RESULTS: Ninety-five patients who underwent mpMRI followed by prostatectomy were included in the study. High Gleason score (score 8-9), radiologist's impression of EPE, and PI-RADS 5 were significantly correlated with EPE in surgical specimens (p = 0.014, p < 0.001, and p < 0.001, respectively). Both ACTCL and ABTCL of patients with EPE were significantly higher than those without EPE in all imaging sequences (p < 0.001 to p = 0.003). The ABTCL has higher accuracy than the ACTCL. Dynamic contrast enhancement (DCE) was the most accurate sequence to measure the contact interface. The recommended cut-off value of ABTCL was 15.0 mm, which had a sensitivity and specificity of 75.86% and 72.09%. Multivariable analysis revealed that the ABTCL > 15 mm and the radiologist's impression on visual assessment were the only two independent predictors for the prediction of EPE (p = 0.048 and p = 0.016, respectively). Improvement of diagnostic performance was achieved when the two factors were combined.

CONCLUSION: The ABTCL has better accuracy than the curvilinear measurement in the prediction of EPE. The optimum sequence for the measurement of the contact surface is the DCE. We recommended using 15.0 mm as a cut-off point.

CLINICAL IMPACT: The addition of the ABTCL measurement showed an increase in diagnostic performance. We encourage radiologists to use the capsular contact measurement in addition to their visual assessment to detect EPE in pre-operative MRI.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Eurboonyanun K, Pisuchpen N, O'Shea A, et al. The absolute tumor-capsule contact length in the diagnosis of extraprostatic extension of prostate cancer. Abdom Radiol (NY). 2021. PMID: 33770224. doi:10.1007/s00261-021-03063-2

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。